view wiki/Make Firmware File.md @ 668:079bb5b22c06 Betatest

Rework charge cycle: The charge counter is increasing decreasing also if the real value is maybe not defined (definition is done for example by a completed charging cycle). This caused some problems with invalid displayed charge per centage values. To avoid this the state of an unknow counter value was introduced. The indication is done by converting the counter into a negativ value.
author Ideenmodellierer
date Sat, 12 Mar 2022 22:48:45 +0100
parents 0e7c16dd774d
children
line wrap: on
line source

# How to Make an Uploadable Firmware File for the OSTC4 #

Generated BIN files from the SMT32 Workbench need modification in order to be installed via the OSTC Companion onto the OSTC4. 

## Build Command Line Tools ##

These can be found in /ostc4pack (For Windows, CPP sources available)

## Run the Tools Manually ##

1. Copy generated BIN files (From the Release or debug directory) into /ostc4pack. Or: Modify .bat files to point to your Release or debug directory.
2. run step1_create_OSTC_RTE_upload.bat and/or step1_create_OSTC4_firmware_upload_bin.bat (Depending on which part you made changes)
3. run step2_create_OSTC4update_bin.bat to create final OSTC4update_xxxxxx.bin, with xxxxxx being the current date in YYMMDD format. This will add important checksums required for the OSTC4's bootloader to accept the file.

## Upload this file with the OSTC Companion software to the OSTC4 ##

See http://forum.heinrichsweikamp.com/read.php?7,19186 on how to get and use the "OSTC companion"