diff Discovery/Src/data_central.c @ 864:fa431d42b5fb
Fix incorrect logging of bailout to Open Circuit when using the best gas.
This happened because the starting gas used for 'best gas' calculation
was a diluent - in most cases not a problem as the same gas is also
used as a bailout gas. Now use the 'first' open circuit gas configured as the
starting point.
Also fixes the problem of a custom bailout gas not being logged as such,
and consequently not being shown as bailout in the on-device log.
author | heinrichsweikamp |
---|---|
date | Mon, 22 Jul 2024 16:38:36 +0200 |
parents | dd7ce655db26 |
children | e373e90a48db |
line wrap: on
line diff
--- a/Discovery/Src/data_central.c Mon Oct 09 11:23:27 2023 +0200 +++ b/Discovery/Src/data_central.c Mon Jul 22 16:38:36 2024 +0200 @@ -547,12 +547,19 @@ nitrogen -= helium; - if((lifeData->actualGas.nitrogen_percentage != nitrogen) || (lifeData->actualGas.helium_percentage != helium) || (lifeData->actualGas.AppliedDiveMode != DIVEMODE_OC)) + if ((lifeData->actualGas.nitrogen_percentage != nitrogen) || (lifeData->actualGas.helium_percentage != helium) || lifeData->actualGas.AppliedDiveMode != DIVEMODE_OC) { - stateUsedWrite->events.manualGasSet = 1; - stateUsedWrite->events.info_manualGasSetHe = helium; - stateUsedWrite->events.info_manualGasSetO2 = oxygen; + if (stateUsed->diveSettings.ccrOption) { + stateUsedWrite->events.bailout = 1; + stateUsedWrite->events.info_bailoutHe = helium; + stateUsedWrite->events.info_bailoutO2 = oxygen; + } else { + stateUsedWrite->events.manualGasSet = 1; + stateUsedWrite->events.info_manualGasSetHe = helium; + stateUsedWrite->events.info_manualGasSetO2 = oxygen; + } } + if( lifeData->actualGas.setPoint_cbar != setpoint_cbar) { stateUsedWrite->events.setpointChange = 1;