Mercurial > public > ostc4
diff Discovery/Inc/t5_gauge.h @ 433:aa286a4926c2 Improve_BatteryGasGauge
Detect startup after power off:
Introduced a variable in memory area which is not initialized during startup. In case of a start from power off the memory cell will be initialized (persistant as long as RTE is powered) and charge counter is set to 0 signaling the user to do a complete charge to calibrate the counter.
author | ideenmodellierer |
---|---|
date | Sun, 23 Feb 2020 21:09:56 +0100 |
parents | 39c147e47c1c |
children |