diff wiki/Detailed CPU1-Discovery Project.md @ 643:5149cd644fbc

Reimplemented charger status generation (deactivated): Sometimes the original implementation never reached the state fully charged for unknown reason. The code already contained a function which set the status to fully charger even it was not signaled by the charger (in case voltage is > 4.1V). The new implementation changed the handling of the detection and the OSTC showing the problem now reaches the fully charger status. As the new implementation is still under test it is deactivated => original implementation is active per default
author Ideenmodellierer
date Wed, 24 Mar 2021 22:06:00 +0100