comparison Discovery/Src/settings.c @ 652:f6212495f34f

Allow setpoint starting at 0.4 ppO2: Some rebreathers (e.g. Sentinel) start with a ppO2 of 0.4 Bar => modified range check to allow this value (was 0.5 before)
author Ideenmodellierer
date Mon, 19 Apr 2021 20:34:53 +0200
parents 5f0d3dce5ef4
children 890440ab993a
comparison
equal deleted inserted replaced
651:7b5a063f080f 652:f6212495f34f
680 } 680 }
681 /* SSetpointLine setpoint[1 + NUM_GASES]; 681 /* SSetpointLine setpoint[1 + NUM_GASES];
682 */ 682 */
683 for(int i=1; i<=NUM_GASES;i++) 683 for(int i=1; i<=NUM_GASES;i++)
684 { 684 {
685 if(Settings.setpoint[i].setpoint_cbar < 50) 685 if(Settings.setpoint[i].setpoint_cbar < MIN_PPO2_SP_CBAR)
686 { 686 {
687 Settings.setpoint[i].setpoint_cbar = 50; 687 Settings.setpoint[i].setpoint_cbar = MIN_PPO2_SP_CBAR;
688 corrections++; 688 corrections++;
689 } 689 }
690 if(Settings.setpoint[i].setpoint_cbar > 160) 690 if(Settings.setpoint[i].setpoint_cbar > 160)
691 { 691 {
692 Settings.setpoint[i].setpoint_cbar = 160; 692 Settings.setpoint[i].setpoint_cbar = 160;