comparison Small_CPU/Inc/batteryGasGauge.h @ 669:c1e203ffb478 Betatest

Rework charge cycle: The charge counter is increasing decreasing also if the real value is maybe not defined (definition is done for example by a completed charging cycle). This caused some problems with invalid displayed charge per centage values. To avoid this the state of an unknow counter value was introduced. The indication is done by converting the counter into a negativ value.
author Ideenmodellierer
date Sat, 12 Mar 2022 22:49:09 +0100
parents 1b995079c045
children
comparison
equal deleted inserted replaced
668:079bb5b22c06 669:c1e203ffb478
33 33
34 #define BATTERY_DEFAULT_VOLTAGE (6.0f) 34 #define BATTERY_DEFAULT_VOLTAGE (6.0f)
35 #define BATTERY_ENDOF_CHARGE_VOLTAGE (4.05f) 35 #define BATTERY_ENDOF_CHARGE_VOLTAGE (4.05f)
36 #define BATTERY_CHARGER_CONNECTED_VOLTAGE (4.2f) 36 #define BATTERY_CHARGER_CONNECTED_VOLTAGE (4.2f)
37 37
38 #define BATTERY_CHARGE_UNKNOWN (-1.0f)
39
38 void init_battery_gas_gauge(void); 40 void init_battery_gas_gauge(void);
39 41
40 float get_voltage(void); 42 float get_voltage(void);
41 float get_charge(void); 43 float get_charge(void);
42 44
43 void battery_gas_gauge_get_data(void); 45 void battery_gas_gauge_get_data(void);
44 void battery_gas_gauge_set_charge_full(void); 46 void battery_gas_gauge_set_charge_full(void);
45 void battery_gas_gauge_set(float percentage); 47 void battery_gas_gauge_set(float percentage);
46 uint8_t battery_gas_gauge_CheckConfigOK(void); 48 uint8_t battery_gas_gauge_CheckConfigOK(void);
47 49
50 uint8_t battery_gas_gauge_isChargeValueValid(void);
51 void battery_gas_gauge_setChargeValueValid(void);
52
53
48 #ifdef __cplusplus 54 #ifdef __cplusplus
49 } 55 }
50 #endif 56 #endif
51 57
52 #endif /* BATTERY_GAS_GAUGE_H */ 58 #endif /* BATTERY_GAS_GAUGE_H */