comparison Discovery/Src/t7.c @ 840:7e714662b93f Evo_2_23

Development bugfix CO2 LLC: In the previous version the CO2 LLC (lowerleftcorner) was displayed even if no CO2 sensor was present or active. In the new version it will only be displayed if an sensor is active.
author Ideenmodellierer
date Sun, 07 Jan 2024 21:21:58 +0100
parents 18946846b95b
children ba1aebc6d5af
comparison
equal deleted inserted replaced
839:061174d88af9 840:7e714662b93f
3210 if((selection_custom_field == LCC_SimPpo2) && (settingsGetPointer()->dive_mode != DIVEMODE_PSCR)) 3210 if((selection_custom_field == LCC_SimPpo2) && (settingsGetPointer()->dive_mode != DIVEMODE_PSCR))
3211 { 3211 {
3212 selection_custom_field++; 3212 selection_custom_field++;
3213 } 3213 }
3214 #endif 3214 #endif
3215 #ifdef ENABLE_CO2_SUPPORT
3216 if((selection_custom_field == LCC_CO2) && (settingsGetPointer()->co2_sensor_active == 0))
3217 {
3218 selection_custom_field++;
3219 }
3220
3221 #endif
3222
3215 if(selection_custom_field >= LLC_END) 3223 if(selection_custom_field >= LLC_END)
3216 { 3224 {
3217 selection_custom_field = LLC_Empty; 3225 selection_custom_field = LLC_Empty;
3218 } 3226 }
3219 } 3227 }