Mercurial > public > ostc4
annotate Common/Inc/decom.h @ 471:73da921869d9 fix-bat-2
bugfix: implement battery charge percentage in dive header
This commit is (much) less trivial than the related 919e5cb51c92.
First, rename the CCRmode attribute (corresponding to byte Ox59) of
the SLogbookHeaderOSTC3. This byte (according to the hwOS interface
document) does not contain any CCR related value, but it contains
"battery information". Already since 2017, this byte is used from
libdivecomputer to interface the charge percentage. So, its
renamed from CCRmode to batteryCharge, to reflect its true purpose.
Now, simply add a batteryCharge attribute to the SLogbookHeader
(and see below why that is possible, without breaking things).
The remaining changes are trivial to implement battery charge
percentage in dive header.
Caveat: do not get confused by the exact role of the individual
logbook header types. SLogbookHeaderOSTC3 is the formal type of
the logbook format that the OSTC4 produces. This format is
supposed to identical to the format, as is used in hwOS for the
series of small OSTCs. Only some values of attributes are different.
For example, the OSTC4 supports VPM, so byte 0x79 (deco model used
for this dive) also has a value for VPM. But the SLogbookHeader
type, despite its name and structure, is *not* a true logbook
header, as it includes attributes that are not available in the
SLogbookHeaderOSTC3 formal header type.
Signed-off-by: Jan Mulder <jan@jlmulder.nl>
author | Jan Mulder <jlmulder@xs4all.nl> |
---|---|
date | Wed, 22 Apr 2020 13:08:57 +0200 |
parents | 239aa58b533d |
children | 1b995079c045 |
rev | line source |
---|---|
38 | 1 /////////////////////////////////////////////////////////////////////////////// |
2 /// -*- coding: UTF-8 -*- | |
3 /// | |
4 /// \file Common/Inc/decom.h | |
5 /// \brief This code is used to calculate desat, calculated by RTE and send to Firmware | |
6 /// \author Heinrichs Weikamp | |
7 /// \date 22-Feb-2016 | |
8 /// | |
9 /// $Id$ | |
10 /////////////////////////////////////////////////////////////////////////////// | |
11 /// \par Copyright (c) 2014-2018 Heinrichs Weikamp gmbh | |
12 /// | |
13 /// This program is free software: you can redistribute it and/or modify | |
14 /// it under the terms of the GNU General Public License as published by | |
15 /// the Free Software Foundation, either version 3 of the License, or | |
16 /// (at your option) any later version. | |
17 /// | |
18 /// This program is distributed in the hope that it will be useful, | |
19 /// but WITHOUT ANY WARRANTY; without even the implied warranty of | |
20 /// MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the | |
21 /// GNU General Public License for more details. | |
22 /// | |
23 /// You should have received a copy of the GNU General Public License | |
24 /// along with this program. If not, see <http://www.gnu.org/licenses/>. | |
25 ////////////////////////////////////////////////////////////////////////////// | |
26 | |
27 #ifndef DECOM_H | |
28 #define DECOM_H | |
29 | |
30 #include "data_central.h" | |
31 | |
32 # define WATER_VAPOUR_PRESSURE (0.0493f) // Schreiner 1971 | |
33 | |
34 void decom_get_inert_gases(const float ambient_pressure_bar,const SGas* pGas, float* fraction_nitrogen, float* fraction_helium ); | |
35 void decom_tissues_exposure(int period_in_seconds, SLifeData* pLifeData); | |
36 void decom_tissues_exposure2(int period_in_seconds, SGas* pActualGas, float pressure_ambient_bar, float *tissue_N2_selected_stage, float *tissue_He_selected_stage); | |
37 float decom_schreiner_equation(float *initial_inspired_gas_pressure, float *rate_change_insp_gas_pressure, float *interval_time_minutes, const float *gas_time_constant, float *initial_gas_pressure); | |
38 void decom_reset_with_1000mbar(SLifeData * pLifeData); | |
129
239aa58b533d
Added function to initialise structures with the actual ambient pressure
Ideenmodellierer
parents:
38
diff
changeset
|
39 void decom_reset_with_ambientmbar(float ambient, SLifeData * pLifeData); |
38 | 40 |
41 void decom_tissues_exposure_stage_schreiner(int period_in_seconds, SGas* pGas, float starting_ambient_pressure_bar, float ending_ambient_pressure_bar, | |
42 float* pTissue_nitrogen_bar, float* pTissue_helium_bar); | |
43 void decom_CreateGasChangeList(SDiveSettings* pInput, const SLifeData* lifeData); | |
44 uint8_t decom_tissue_test_tolerance(float* Tissue_nitrogen_bar, float* Tissue_helium_bar, float GF_value, float depth_in_bar_absolute); | |
45 void decom_tissues_desaturation_time(const SLifeData* pLifeData, SLifeData2* pOutput); | |
46 void test_decom_CreateGasChangeList(void); | |
47 | |
48 float decom_calc_ppO2(const float ambiant_pressure_bar, const SGas* pGas); | |
49 void decom_oxygen_calculate_otu(float* oxygen_otu, float pressure_oxygen_real); | |
50 void decom_oxygen_calculate_otu_degrade(float* oxygen_otu, long seconds_since_last_dive); | |
51 void decom_oxygen_calculate_cns_degrade(float* oxygen_cns, long seconds_since_last_dive); | |
52 void decom_oxygen_calculate_cns(float* oxygen_cns, float pressure_oxygen_real); | |
53 void decom_oxygen_calculate_cns_stage_SchreinerStyle(int period_in_seconds, SGas* pGas, float starting_ambient_pressure_bar, float ending_ambient_pressure_bar, float* oxygen_cns); | |
54 void decom_oxygen_calculate_cns_exposure(int period_in_seconds, SGas* pActualGas, float pressure_ambient_bar, float* oxygen_cns); | |
55 uint8_t decom_get_actual_deco_stop(SDiveState* pDiveState); | |
56 | |
57 // wird nur in smallCPU verwendet: | |
58 int decom_calc_desaturation_time(float* Tissue_nitrogen_bar, float* Tissue_helium_bar, float surface_pressure_bar); | |
59 | |
60 #endif /* DECOM_H */ | |
61 |