annotate ostc4pack/step0_copy_release.bat @ 707:e81afd727993

Menu cleanup rebreather specific settings: In the previous version the selection for Fix setpoint or sensor was in the deco menu and the Fallback option in the hardware menu. As they have a dependency and are only relevant for rebreather operation, they have been moved into the extra menu which is containing rebreather related data and which is only visible in rebreather mode.
author Ideenmodellierer
date Thu, 03 Nov 2022 20:44:21 +0100
parents fd47e5631b9d
children
Ignore whitespace changes - Everywhere: Within whitespace: At end of lines:
rev   line source
266
fd47e5631b9d Added batch to copy bins from release folder
ideenmodellierer
parents:
diff changeset
1 copy ..\..\OSTC4_Firmware\Release\OSTC4_Firmware.bin OSTC4_Firmware.bin /V /Y
fd47e5631b9d Added batch to copy bins from release folder
ideenmodellierer
parents:
diff changeset
2 copy ..\..\OSTC4_RTE\Release\OSTC4_RTE.bin OSTC4_RTE.bin /V /Y
fd47e5631b9d Added batch to copy bins from release folder
ideenmodellierer
parents:
diff changeset
3