Devbugfix UART buffer cleaning:
In the previous version a buffer cleaning function was used which resets the ringbuffer read index. As result the processing of data was stopped until the DMA write comes to the index 0. When reaching it the complete buffer was proceeded including possibly invalid data.
The usage of the cleanbuffer function was replaced by the flush buffer function (meaning the data is discarded but the data index is maintained). There was already a function for this. Because the function was 99% the same as the read function, it was integrated into the ReadData function. Calling the function with parameter flush = 1 will result in a buffer flush.
The workaround of the previous revision was updated to only be applied in case a DiveO2 sensor is operated in stand alone mode.
11 1. Copy generated BIN files (From the Release or debug directory) into /ostc4pack. Or: Modify .bat files to point to your Release or debug directory.
13 3. run step2_create_OSTC4update_bin.bat to create final OSTC4update_xxxxxx.bin, with xxxxxx being the current date in YYMMDD format. This will add important checksums required for the OSTC4's bootloader to accept the file.