Mercurial > public > mk2
changeset 580:32448d5ca734
BUGFIX: GasVolume should not count bottom time/depth in CCR mode.
author | JeanDo |
---|---|
date | Tue, 24 Apr 2012 23:51:03 +0200 (2012-04-24) |
parents | fff1d38625f0 |
children | 855a00c21d0c |
files | code_part1/OSTC_code_asm_part1/changelog.txt code_part1/OSTC_code_c_part2/p2_deco.c code_part1/OSTC_code_c_part2/p2_deco.o |
diffstat | 3 files changed, 2 insertions(+), 1 deletions(-) [+] |
line wrap: on
line diff
--- a/code_part1/OSTC_code_asm_part1/changelog.txt Tue Apr 24 23:47:13 2012 +0200 +++ b/code_part1/OSTC_code_asm_part1/changelog.txt Tue Apr 24 23:51:03 2012 +0200 @@ -3,6 +3,7 @@ NEW: Custom Functions III menu (CF64-CF95) BUGFIX: Missed deco stops issue BUGFIX: Timeout for 2nd page of Gas Setup +BUGFIX: GasVolume checks for a gas-switch before the first stop New in 2.21: BUGFIX: GF warning in logbook memory
--- a/code_part1/OSTC_code_c_part2/p2_deco.c Tue Apr 24 23:47:13 2012 +0200 +++ b/code_part1/OSTC_code_c_part2/p2_deco.c Tue Apr 24 23:51:03 2012 +0200 @@ -2340,7 +2340,7 @@ gas = char_I_first_gas - 1; bottom_usage = (float) read_custom_function(56); - if( bottom_usage > 0.0 ) + if( char_I_const_ppO2 == 0 && bottom_usage > 0.0 ) volumes[gas] = (char_I_bottom_depth*0.1 + 1.0) // Use Psurface = 1.0 bar. * char_I_bottom_time // in minutes.