Mercurial > public > mk2
view code_part1/OSTC_code_asm_part1/sleepmode.asm @ 785:b0c96aaa86e4
add ceiling display, no turkish language support anymore
author | heinrichsweikamp |
---|---|
date | Sun, 29 Jun 2014 15:13:32 +0200 |
parents | fac7710ab84e |
children | c50296c3059e |
line wrap: on
line source
; OSTC - diving computer code ; Copyright (C) 2008 HeinrichsWeikamp GbR ; This program is free software: you can redistribute it and/or modify ; it under the terms of the GNU General Public License as published by ; the Free Software Foundation, either version 3 of the License, or ; (at your option) any later version. ; This program is distributed in the hope that it will be useful, ; but WITHOUT ANY WARRANTY; without even the implied warranty of ; MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the ; GNU General Public License for more details. ; You should have received a copy of the GNU General Public License ; along with this program. If not, see <http://www.gnu.org/licenses/>. ; Routines for sleepmode ; written by: Matthias Heinrichs, info@heinrichsweikamp.com ; written: 050520 ; last updated: 090507 ; known bugs: ; ToDo: sleeploop: ; enter sleepmode! ; first check if the 16 hash char are=0 lfsr FSR2, char_O_hash movlw d'16' movwf temp1 sleeploop1: tstfsz POSTINC2 ; Test hash values bra sleeploop2 ; At least one char is not zero -> Do not build hash decfsz temp1,F bra sleeploop1 ; build hash (about 90sek @ 16MHz) call DISP_ClearScreen ; clear DISPLAYTEXT .1 ; "Building MD2 hash" DISPLAYTEXT .2 ; "Please wait..." call deco_hash ; calculate MD2 hash movlb b'00000001' ; Back to Bank1 sleeploop2: call DISP_DisplayOff ; display off call disable_rs232 ; disable UART module ; Save surface mode custom view movff menupos3,EEDATA ; Copy to EEDATA write_int_eeprom d'93' ; Write last selected customview surface mode into EEPROM clrf divemins+0 clrf divemins+1 bcf TRISB,6 bcf TRISB,7 bcf PORTB,6 bcf PORTB,7 ; Disable UART sleeploop_loop: btfsc oneminupdate ; one minute in sleep? rcall onemin_sleep ; do oneminute tasks, e.g. calculate desaturation btfsc onesecupdate ; one second in sleep? rcall onesec_sleep ; check switches, check pressure sensor, etc. btfss sleepmode ; wake up? (This bit will be set in other routines) goto restart ; yes nop sleep ; Sleep until Timer1 will wake up the device nop bra sleeploop_loop ; do loop until someting happens onemin_sleep: call get_battery_voltage ; get battery voltage btfsc enter_error_sleep ; Enter Fatal Error Routine? call fatal_error_sleep ; Yes (In Sleepmode_vxx.asm!) ;---- adjust airpressure compensation any 15 minutes incf divemins+1,F ; counts to 14... movlw d'14' cpfsgt divemins+1 bra onemin_sleep2 ; 15 minutes not done! clrf divemins+1 ; reset counter rcall pressuretest_sleep_fast ; Gets pressure without averaging (faster!) SAFE_2BYTE_COPY amb_pressure_avg, amb_pressure ; copy for compatibility call check_temp_extrema ; Check for temperature extremas call deco_calc_CNS_decrease_15min ; compute CNS decay in sleep only movlb b'00000001' movff last_surfpressure_15min+0,last_surfpressure_30min+0 ; save older airpressure movff last_surfpressure_15min+1,last_surfpressure_30min+1 ; save older airpressure SAFE_2BYTE_COPY amb_pressure, last_surfpressure_15min ; save new airpressure GETCUSTOM15 d'7' ; loads max_sufpressure into lo, hi movff lo,sub_a+0 ; max. "allowed" airpressure in mbar movff hi,sub_a+1 movff last_surfpressure_15min+0,sub_b+0 movff last_surfpressure_15min+1,sub_b+1 call sub16 ; sub_c = sub_a - sub_b btfss neg_flag ; Is 1080mbar < amb_pressure ? bra onemin_sleep2 ; NO: current airpressure is lower then "allowed" airpressure, ok! ; not ok! Overwrite with max. "allowed" airpressure GETCUSTOM15 d'7' ; loads max_sufpressure into lo, hi movff lo,last_surfpressure_15min+0 ; max. "allowed" airpressure in mbar movff hi,last_surfpressure_15min+1 ; max. "allowed" airpressure in mbar onemin_sleep2: SAFE_2BYTE_COPY amb_pressure, int_I_pres_respiration ; LOW copy pressure to deco routine GETCUSTOM8 d'11' ; Saturation multiplier % movff WREG,char_I_saturation_multiplier GETCUSTOM8 d'12' ; Desaturation multiplier % movff WREG,char_I_desaturation_multiplier call deco_calc_wo_deco_step_1_min ; "calc_tissue_sleep" movlb b'00000001' ; RAM Bank1 selected bcf oneminupdate ; all done return onesec_sleep: call test_charger ; charger on? btfss nofly_active bra onesec_sleep_nonofly bsf LED_blue ; Set nofly LED nop sleep nop onesec_sleep_nonofly: bcf LED_blue ; Clear nofly LED incf divemins+0,F ; counts to #test_pressure_in_sleep (5) movlw d'5' cpfsgt divemins+0 ; here: temp variable bra onesec_sleep1 ; #test_pressure_in_sleep not done yet clrf divemins+0 rcall pressuretest_sleep_fast ; Gets pressure without averaging (faster!) SAFE_2BYTE_COPY amb_pressure_avg, amb_pressure ; copy for compatibility ; compare current ambient pressure with threshold CF6==1160mbar. GETCUSTOM15 d'6' ; loads pressure threshold into lo,hi movff lo,sub_a+0 ; power on if ambient pressure is greater threshold movff hi,sub_a+1 SAFE_2BYTE_COPY amb_pressure_avg, sub_b call sub16 ; Is (1160mbar - averaged(amb_pressure)) < 0 ? bsf sleepmode btfsc neg_flag ; Wake up from Sleep? bcf sleepmode ; amb_pressure>pressure_offset_divemode: wake up! onesec_sleep1: bcf onesecupdate ; all done. btfsc switch_left bra onesec_sleep1a btfsc switch_right bra onesec_sleep1a ; No button pressed bcf INTCON,INT0IF ; Clear flag bcf INTCON3,INT1IF ; Clear flag bcf switch_right bcf switch_left bcf T0CON,TMR0ON ; Stop Timer 0 return onesec_sleep1a: ; At least one button pressed.... bcf INTCON,INT0IF ; Clear flag bcf INTCON3,INT1IF ; Clear flag bcf switch_right bcf switch_left bcf T0CON,TMR0ON ; Stop Timer 0 bcf sleepmode ; wake up! ; Restart altimeter averaging, so next averaging starts right over... call altimeter_restart return pressuretest_sleep_fast: ; Get pressure without averaging (Faster to save some power in sleep mode) call get_temperature_start ; and start temperature integration (73,5us) sleep nop sleep nop sleep ; Wait at least 35ms (every 16.5ms Timer1 wakeup) call get_temperature_value ; State 1: Get temperature call get_pressure_start ; Start pressure integration. sleep nop sleep nop sleep ; Wait at least 35ms (every 16.5ms Timer1 wakeup) call get_pressure_value ; State2: Get pressure (51us) clrf temperature_avg+0 clrf temperature_avg+1 clrf amb_pressure_avg+0 clrf amb_pressure_avg+1 ; clear for sleep routine call calculate_compensation ; calculate temperature compensated pressure (233us) return fatal_error_sleep: call DISP_DisplayOff ; display off call disable_rs232 ; disable UART module bcf TRISB,6 bcf TRISB,7 bcf PORTB,6 bcf PORTB,7 ; Disable UART fatal_error_sleep_loop: movff fatal_error_code,temp4 movlw d'15' movwf temp1 fatal_error_sleep_loop1: sleep nop decfsz temp1,F bra fatal_error_sleep_loop1 fatal_error_sleep_loop2: call get_battery_voltage ; get battery voltage btfss enter_error_sleep ; REALLY enter Fatal Error Routine? goto restart ; No bsf LED_red clrwdt WAIT10US d'5' bcf LED_red sleep nop decfsz temp4,F bra fatal_error_sleep_loop2 bra fatal_error_sleep_loop