Mercurial > public > mk2
view code_part1/OSTC_code_asm_part1/changelog.txt @ 812:86efd57c158c
minor italian update
author | heinrichsweikamp |
---|---|
date | Wed, 25 Mar 2015 18:24:58 +0100 |
parents | 88e1a4e3e05b |
children | e50e76f99636 |
line wrap: on
line source
New in 3.03: Stable Release BUGFIX: 1st line in logbook was not displayed in rare cases (2C hardware) New in 3.02: Stable Release BUGFIX: Divetime had unwanted "." behind the minutes New in 3.01: Stable Release BUGFIX: Entry time in logbook when dive was around midnight BUGFIX: Show manually set O2 (Gas 6) correctly BUGFIX: Show dives with >999mins divetime correctly New in 3.00: Stable Release BUGFIX: Fix color codes 192-223 (Mk.2 and 2N only) New in 2.95: BETA Version BUGFIX: Surface interval was paused during simulator BUGFIX: False Bailout and Gas 6 flags in logbook BUGFIX: Color of "Menu?" in divemode New in 2.94: BETA Version BUGFIX: False bailout flag in logbook NEW: On-Time counter for better battery information NEW: Store useage timer in logbook header (Byte 54, see documentation) NEW: CF74: Battery Timeout [min] - Battery symbol will blink if the OSTC was longer in active mode (since the last _full_ charge) then CF74. Default=1800 (30hours) New in 2.93: BETA Version NEW: Show Gas change countdown if CF55>0 CHANGE: Graphical velocity on by default (CF60=1) NEW: Ceiling display (GF_hi based) in divemode CHANGE: No turkish language support anymore BUGFIX: Gas volume computation when using several travel mixes New in 2.91: BETA Version New: Show bailout event in internal logbook New in 2.90: Stable Release BUGFIX: CNS calculation in decoplan should track gas (no marked changes anymore) New in 2.81: BUGFIX: Show bailout list if first bailout gas <> gas 1 BUGFIX: Italian language fix (Divemode menu) BUGFIX: Gas change depth display in divemode menu (OSTC 2C only) New in 2.80: Stable Release New in 2.75: BETA Version - Do NOT use for diving BUGFIX: ppO2 display in PSCR Mode New in 2.74: BETA Version - Do NOT use for diving BUGFIX: remove ghost image (On 2C only) during first second in sleep mode CHANGE: Remove CF55 from decolist TODO: show gas change stops different from decostops BUGFIX: FTTS>9min in OSTC 2C hardware NEW: Show the bailout list in surfacemode (CC Modes) CHANGE: Faster button response New in 2.73: BETA Version - Do NOT use for diving BUGFIX: Show ppo2 of change depth in gas setup for OSTC 2C hardware New in 2.72: BETA Version - Do NOT use for diving CHANGE: Some minor code cleanups CHANGE: Spanish language updates New in 2.71: BETA Version - Do NOT use for diving! NEW: Indicate First Gas (OC) as Better Gas in Bailout list BUGFIX: Clear end-of-dive countdown properly when descending again New in 2.70: Intermediate release for OSTC 2C users (Language support) New in 2.65: BETA Version - Do NOT use for diving! CHANGE: show old decoplan after gas change until new decoplan is ready CHANGE: "ostc3-style" menu titles NEW: Vault date and time during update New in 2.63: BETA Version - Do NOT use for diving! BUGFIX: no flicker when powering on CHANGE: 256ms switch debounce timer New in 2.62: BETA Version - Do NOT use for diving! BUGFIX: CNS compute. NOAA tables are in ATA, not bar New in 2.61: BETA Version - Do NOT use for diving! CHANGE: Set default for CF64 (Color inactive) to 103 (light blue) BUGFIX: Vault low_depth too BUGFIX: Ascent to first stop in finer steps (Deko spikes) New in 2.60: BETA Version - Do NOT use for diving! CHANGE: Removed "Mix type" Icons and CF43 CHANGE: Hardware4 support CHANGE: Use 4Bytes in EEPROM for diluents (Same as OC gases) NEW: Show active gas indicator below first gas in surfacemode UPDATE: OSTC interface description file NEW: Hard-coded min. Values for CF00 and CF01 CHANGE: Set cursor to "Exit" when leaving some sub-menus New in 2.59: BETA Version - Do NOT use for diving! CHANGE: Set CF17 (ppo2_warning_low) low level to 0.16bar Known Issue: CFIII Menu not checked from cf_checker routine New in 2.58: BETA Version - Do NOT use for diving! NEW: Confirmation when marker is set BUGFIX: Decoplan update after GF change NEW: CF70: Safety Stop Duration [s] NEW: CF71: Safety Stop Start Depth [m] NEW: CF72: Safety Stop End Depth [m] NEW: CF73: Safety Stop Reset Depth [m] New in 2.57: BETA Version - Do NOT use for diving! CHANGE: GF_hi default now 85% (CF33) NEW: aGF: Alternative GF (CF67 and CF68). Can be switched underwater if CF69=1 NEW: CF67: aGF_lo [%] NEW: CF68: aGF_hi [%] NEW: CF69: Allow GF change (underwater) CHANGE: Deco model default now is L16-GF OC (OC, GF-Deco) New in 2.56: BETA Version - Do NOT use for diving! BUGFIX: Gas volumes when many tanks and stops BUGFIX: show first diluent in simulator result screen (Instead of first gas) New in 2.55: BETA Version - Do NOT use for diving! NEW: Allow any Diluent to be "First Gas" in CCR mode New in 2.54: BETA Version - Do NOT use for diving! BUGFIX: Allow Diluents with more then 50% He CHANGE: "Max." Depth text position New in 2.53: BETA Version - Do NOT use for diving! NEW: 5 Gases extra for CC TODO: Text 61,229,110,111,229,230,231,232 TXT_DIL_C, TXT_DIL5 update NEW: Divisor Decoplan (CF25) stores entire decoplan in logbook NEW: CF29 stored in divelog header (Byte 52) BUGFIX: Gas Setup when using "ERR" Gases (e.g. NX17) New in 2.51: BETA Version - Do NOT use for diving! NEW: Saves last selected custom view for surface mode and dive mode NEW: Gaslist highlights "better gas" in divemode NEW: Cursor is in front of the "better gas" automatically New in 2.50 Stable: INFO: This update will reset all Custom Functions and gases to defaults BUGFIX: Divetime display in Gauge mode New in 2.29: INFO: This update will reset CFIII menu to defaults BETA Version - Do NOT use for diving! NEW CF66: Show GF in NDL (If GF > CF08) NEW: Show total dives in Battery Information menu CHANGE: CF01 default to 75cm New in 2.28: BETA Version - Do NOT use for diving! BUGFIX: Blink better gas in bailout case (if CF42=1) CHANGE: Surface screen layout change BUGFIX: Use CF01 for end-of-dive detection CHANGE: CF01 default to 50cm New in 2.27: BETA Version - Do NOT use for diving! BUGFIX: Reset CFIII on update New in 2.26: BETA Version - Do NOT use for diving! CHANGE: Safety stop behaviour BUGFIX: Reset CFIII Menu New in 2.25: BETA Version - Do NOT use for diving! NEW: CF65: Show a safety stop for no-deco dives New in 2.24: BETA Version - Do NOT use for diving! BUGFIX: CNS for pSCR-GF New in 2.23: BETA Version - Do NOT use for diving! NEW: CF64: Configures color for inactive gases NEW: Deco mode "pSCR-GF": Computes deco and CNS based on pSCR parameters (CF62/63) New in 2.22: BETA Version - Do NOT use for diving! NEW: Custom Functions III menu (CF64-CF95) BUGFIX: Missed deco stops issue BUGFIX: Timeout for 2nd page of Gas Setup BUGFIX: GasVolume checks for a gas-switch before the first stop NEW: Battery statistics reset when battery is fully charged New in 2.21: BUGFIX: GF warning in logbook memory NEW: Compute ppO2 for pSCR diving NEW: CF61: Show pSCR ppO2 in customview NEW: CF62: pSCR O2 Drop in percent NEW: CF63: pSCR counterlung ratio 1/x BUGFIX: CF55 behaviour New in 2.20: Stable Release New in 2.10 beta: BETA Version - Do NOT use for diving! BUGFIX: Spurious logbook read issue BUGFIX: Improved stability for bootloader v2 New in 2.09 beta: BETA Version - Do NOT use for diving! BUGFIX: small layout fixes BUGFIX: Show NDL after deco is done New in 2.08 beta: BETA Version - Do NOT use for diving! NEW: Show change gas depth below gaslist (in divemode) New in 2.07 beta: BETA Version - Do NOT use for diving! NEW: Added GF surface display (when > CF08). BUGFIX: spurious random NDL>0 during deco dive CHANGE: Moved "Bailout" to top of SetPoint list CHANGE: Speed optimizations in deco code New in 2.06 beta: BETA Version - Do NOT use for diving! CHANGE: NDL routine faster/more precise simulation BUGFIX: CCR air mode: should not blink for my bailout (bug #66) BUGFIX: Spurious stop order when simulating deadly fast ascent BUGFIX: N2_ratio/He_ratio[] not inited at boot time. CHANGE: Turkish text for velocity. New in 2.05 beta: BETA Version - Do NOT use for diving! BUGFIX: German text layout in Divemode NEW: Always show numeric velocity... NEW: DISPLAY Brightness setting New in 2.04 beta: BETA Version - Do NOT use for diving! BUGFIX: Missing surface pressure for CNS in decoplan. BUGFIX: Surface desat factor missing for Interval planning in GF mode. CHANGE: Velocity display updated every second NEW: CF60: Show graphical velocity indicator (Ascend only) NEW: Added turkish language New in 2.03 beta: BETA Version - Do NOT use for diving! BUGFIX: Logbook write New in 2.02 beta: BETA Version - Do NOT use for diving! NEW: Cave divers consomation display and alarm (CF59). CHANGE: SAC (CF56/CF57) in range 5..50 l/min (no more decimal). NEW: 32MHz mode: computes twice faster. BUGFIX: Hang when deco table is full (more than 32 stops). New in 2.01 beta: BUGFIX: No decodata in logbook for apnea dives New in 2.00 Stable: Stable release BUGFIX: Fixing 32kB boundary read for logbook New in 1.98 beta: BUGFIX bad first Tp° and ceiling values in logbook curves. New in 1.97 beta: NEW: Logbook displays ceilings and temperature curve. BUGFIX: Decoplanner accumulates CNS during ascent. NEW: Decoplanner warns in red if CNS is too high. NEW: Decoplanner OC volumes in liters (or bars), up to 65000. NEW: Released also in Russian language BUGFIX: SetPoint store in Profile New in 1.95 beta: CHANGE: 0.98bar equal 10m depths with salinity set to 1.00kg/l New in 1.94 beta: Pre-Release for 2.0 Stable BUGFIX: CNS was not cleared with a "Reset Deco" CHANGE: Max. depth for simulator now 120m BUGFIX: Ascend threshold in high altitude mode New in 1.93 beta: BETA Version - Do NOT use for diving! BUGFIX: blinking fixed setpoint if actual setpoint lower then physically possible BUGFIX: SetPoint recording for logbook BUGFIX: Divetime seconds synced with stopwatch start NEW: End-of-Dive countdown displayed after surfacing New in 1.92 beta: BETA Version - Do NOT use for diving! BUGFIX: warning color for ppO2>3,3bar and ppO2<6,55bar fixed BUGFIX: Start SetPoint is attached to first depth sample in logbook profile BUGFIX: Simulator menu collided with descent counter in Apnea mode BUGFIX: Display hypoxic air in divemode (bug #41) CHANGE: Gas change indication is displayed in yellow New in 1.91 beta: BETA Version - Do NOT use for diving! BUGFIX: Ignore depths>130m in PC simulation BUGFIX: Avoid spurious CF55 stops with 3 gas or more BUGFIX: Average depth in Logbook (For dives made with >=1.91) BUGFIX: Logbook time scale (squares are 10min * 10m) BUGFIX: Bühlmann half-times rounded to the minute BUGFIX: Protect again rare race contition on pressure/temperature BUGFIX: Time is now accurate CHANGE: CF02 now allows delay of more then 240seconds CHANGE: First gas do not reset change depth CHANGE: Logbook format 21: store & shows dive model (sat/desat or GF_low/high factors), CNS profile, GF profile. WARNING: the upgrade is not reversible without loosing all your profiles. NEW: "Quit Sim" in divemode simulator menu for exiting the simulation NEW: Allow -2:00 to +2:00 adjustement per day (CF48). NEW: 1/10/100 steps in CF menu NEW: 64kByte Logbook (Doubled capacity compared to 1.90) NEW: Additional dive interval for simulator and decoplaning NEW: Negative temperatures in logbook and battery information menu NEW: Screen dump support New in 1.90 Stable: Stable release New in 1.89 beta: BETA Version - Do NOT use for diving! NEW: ppO2 in case of a loop flush can be displayed in CCR mode NEW: Fixed Setpoint with color warnings BUGFIX: Fixed Setpoint behavior >2,55bar with CF38=ON NEW: Future TTS also available in no-deco phase of dive New in 1.88 beta: BETA Version - Do NOT use for diving! CHANGE: CF warning window moved to upper right corner BUGFIX: Gas4 fixed NEW: Future TTS (@xx Variant) in Custom View (Divemode) NEW: CF58 (0-10 min): Computes Future TTS in xx min New in 1.87 beta: BETA Version - Do NOT use for diving! CHANGE: Runtime simulator faster BUGFIX: "Active?" list in Divemode NEW: Display CNS in decoplan NEW: Colored stops in decoplan (CF55 > 0) NEW: 115kbaud/s bootloader NEW: Colored battery sign when charging (yellow) or charged (green) CHANGE: Battery symbol filled BUGFIX: Apply salinity for ceiling warning CHANGE: Gas Setup page 2 reworked (MOD depth default) BUGFIX: x-scale in Logbook fixed CHANGE: Some typos in English text NEW: Display ppO2[Diluent] in CCR modes NEW: Display EAD/END in OCR and CCR modes New in 1.86 beta: BETA Version - Do NOT use for diving! BUGFIX: Average depth in Logbook fixed BUGFIX: Stand-alone simulator New in 1.85 beta: BETA Version - Do NOT use for diving! BUGFIX: zero gas rate (bug bb28) BUGFIX: Safer rounding (bug bb29) CHANGE: making the seconds display in divemode smoother New in 1.84 beta: BETA Version - Do NOT use for diving! BUGFIX: NoFly time should not be reseted after dive simulation. NEW: High altitude (Plane/Fly) mode added NEW: Gaslist, Salinity, CNS and Average depth displayed in Logbook NEW: Internal logbook shows Gas changes NEW: Release in French, Spain, English and German (Use correct HEX file!) CHANGE: Set Time menu New in 1.83 beta: BETA Version - Do NOT use for diving! BUGFIX: gas switch NEW: De/Activate gases underwater (Gaslist -> More -> Actve?) NEW: Gas Consumption caluculation in offline simulator (After Decoplan) NEW: CF56 Bottom gas usage (l/min or bar/min) (For Simulator) NEW: CF57 Ascent/deco gas usage (l/min or bar/min) (For Simulator) New in 1.82 beta: BETA Version - Do NOT use for diving! CHANGE: Speed optimization in Logbook NEW: Scale for Profile view in Logbook (10m,10min) New in 1.81 beta: BETA Version - Do NOT use for diving! NEW: Release in French, Spain and English (Use correct HEX file!) CHANGE: ZH-L16 display all stops (up to 96m), as ZH-L16-GF mode BUGFIX: Don't wrap TTS sum (still limit each stop display (not compute) to ~4h) NEW: CF54: =1:Display shallowest stop first (decoplan and divemode) BUGFIX: Inactive gases greyed-out in Simulator results BUGFIX: "Better Gas" now works for Gas 4 and Gas 5, as well NEW: GF_lo and GF_hi stored in logbook BUGFIX: Gradient factor reworked NEW: CF55: Additional delay for gas switch (decoplan, includng divemode) New in 1.80 Stable: Stable release BUGFIX: No Custom view in Surfacemode as default New in 1.76 Beta: BETA Version - Do NOT use for diving! NEW: "beta" is shown for beta versions CHANGE: NoFly and Desaturation time only visible when > 0 CHANGE: "LowBatt!" Warning in Divemode New in 1.75 Beta: BETA Version - Do NOT use for diving! BUGFIX: Decomask in Gauge mode removed NEW: Decoplan rewritten, now has practically unlimited number of stops (OSTC MK.2 only) NEW: Altimeter (OSTC MK.2 only) BUGFIX: Timeout reset in Customview (OSTC MK.2 only) BUGFIX: Surface Interval NEW: Non-Resettable Average Depth (OSTC MK.2 only) NEW: CF41: Mix Type Icons in Surfacemode (OSTC MK.2 only) NEW: CF49: Show Altimeter in Surfacemode (OSTC MK.2 only) NEW: CF50: Show LogMarker in Divemode/Customview (OSTC MK.2 only) NEW: CF51: Show Stopwatch in Divemode/Customview (OSTC MK.2 only) NEW: CF52: Show Tissue Graph in Divemode/Customview (OSTC MK.2 only) NEW: CF53: Show Leading Tissue in Divemode/Customview (OSTC MK.2 only) NEW: CF39: Adjust fixed SetPoint if Diluent ppO2 > SetPoint (OSTC MK.2 only) BUGFIX: Custom view for Apnoe mode disabled BUGFIX: Custom view for Gauge mode adjusted New in 1.74 Beta: BETA Version - Do NOT use for diving! NEW: Added END (Equivalent narcotic depth) for GasSetup CHANGE: Limits for several Custom Functions (OSTC MK.2 only) BUGFIX: Realtime Simulator menu NEW: Customview for Surfacemode (OSTC MK.2 only) NEW: Icon for Tank mix on Surface screen (OSTC MK.2 only) BUGFIX: Stopwatch Reset New in 1.73 Beta: BETA Version - Do NOT use for diving! NEW: Anti-Alised fonts (OSTC MK.2 only) NEW: Removed CF39 - Clock moved into Customview area (OSTC Mk.2 only) NEW: Custom functions menu more comfortable (OSTC Mk.2 only) BUGFIX: Surface interval now correct for repetitive dives CHANGE: Changes in divemode layout (OSTC Mk.2 only) New in 1.72 Beta: BETA Version - Do NOT use for diving! BUGFIX: TTS display while decoplan is displayed CHANGE: Stopwatch reset is blocked for one second after divemode menu exit (OSTC Mk.2 Only) NEW: Gas list is color-coded in Color# Warnings if ppO2 of gas > CF18 (ppO2 High warning) (OSTC Mk.2 Only)) CHANGE: Exchanged "Gaslist" and "Decoplan" in Divemode menu BUGFIX: ppO2 warning for very high ppO2 levels New in 1.71 Beta: BETA Version - Do NOT use for diving! BUGFIX: Custom text can be 23chars again BUGFIX: Simulator descends to exact depth NEW: Added CF39: =1 shows clock in divemode (OSTC Mk.2 only) BUGFIX: Surface Interval not afffected from Simulator CHANGE: "Decosum" changed to "TTS" (Time to Surface) NEW: Up to 16 Deco Stops are displayed in Divemode and Simulator (GF Modes only) NEW: CF40 added (=1: Ceiling violation displayed in Color# Warnings (OSTC Mk.2 Only)) New in 1.70 Stable: Stable release WARNING: This update will reset all Custom Functions! BUGFIX: Gas Changes for Simulator New in 1.65 Beta: This is the 1.70 Stable release candidate BETA Version - Do NOT use for diving! CHANGE: Restored original Gas Setup CHANGE: CF25 (Deco Debug) default to 0 BUGFIX: Velocity warning (CF47) only for ascend New in 1.63 Beta: BETA Version - Do NOT use for diving! CHANGE: CF15 defines threshold for CNS display in Surfacemode (OSTC MK.2 only) NEW: CF48 sets positive clock offset [seconds/24h], added at Midnight BUGFIX: CNS restored after simulation New in 1.62 Beta: BETA Version - Do NOT use for diving! CHANGE: More space around divemode-menu CHANGE: Disabled "Delete Dive" in logbook CHANGE: Simulated dives are no longer stored in the logbook NEW: Simulator is much faster now NEW: New Simulation results screen BUGFIX: CF Warning displayed in Color# Warnings (OSTC Mk.2 only) NEW: Gas Setup sorts Gaslist NEW: Deco Code uses all Gases for forecast New in 1.61 Beta: BETA Version - Do NOT use for diving! CHANGE: "Better Gas" now blinks more eye catching CHANGE: Battery symbol range changed (OSTC Mk.2 Only) NEW: Added CF37: Color# Warnings (OSTC Mk.2 Only) NEW: Color# = 0,4,8,192,196 and 200 (Black or very dim) is ignored (OSTC Mk.2 Only) BUGFIX: History not updated in Simulator mode BUGFIX: Fixed-Setpoint (minimum) ppO2 limited to physically possible value NEW: Depth, CNS, GF, ppO2 and Velocity are Color-coded (OSTC Mk.2 Only) NEW: CF43: Depth [mbar] for color-code display (OSTC Mk.2 Only) NEW: CF44: CNS [%] for color-code display (OSTC Mk.2 Only) NEW: CF45: GF [%] for color-code display (OSTC Mk.2 Only) NEW: CF46: ppO2 [cbar] for color-code display (OSTC Mk.2 Only) NEW: CF47: Velocity [m/min] for color-code display (OSTC Mk.2 Only) CHANGE: Change of color layout (OSTC Mk.2 Only) New in 1.60 Stable: Stable release New in 1.56 Beta: BETA Version - Do NOT use for diving! BUGFIX: Inactive Gases in Divemode greyed out (OSTC Mk.2 only) NEW: Scale in Tissue Graph (OSTC Mk.2 only) NEW: Leading Tissue percent is displayed in Tissue Graph (OSTC Mk.2 only) NEW: Diluent is shown in Pre-Dive screen for CC modes New in 1.55 Beta: BETA Version - Do NOT use for diving! CHANGE: Greyed out gases more readable CHANGE: Removed "Delete All" from Logbook Menu NEW: CF42=1: Active Gas will blink if a better gas is available CHANGE: Returning from Bailout to CCR mode will not reset diluent gas New in 1.54 Beta: BETA Version - Do NOT use for diving! BUGFIX: Freeze at startup New in 1.53 Beta: BETA Version - Do NOT use for diving! CHANGE: License moved into Menu NEW: Quick power on NEW: Not used O2 Sensors are not shown (OSTC1 only) NEW: O2 Board is automatically selected when found within the 1st second in divemode (OSTC1 only) NEW: Quick-View of Gaslist (Pre-Dive Check), press ENTER in Surfacemode New in 1.52 Beta: BETA Version - Do NOT use for diving! NEW: Fixed-Setpoint ppO2 limited to physically possible value BUGFIX: CF32 was displayed wrong on first call NEW: Gas change recommendation in divemode ('*' after Gas) CHANGE: "Const.ppO2 Setup" renamed to "CCR SetPoint Menu" BUGFIX: CF35 now affects all items in surface and divemode NEW: CF36 sets Divemode mask color (OSTC Mk.2 only) BUGFIX: CF15 removed (OSTC Mk.2 only) New in 1.51 Beta: BETA Version - Do NOT use for diving! BUGFIX: PC Simulator mode NEW: CF35 sets standard color BUGFIX: Display startup at very cold ambient temperatures BUGFIX: Battery voltage accuracy BUGFIX: Temperature accuracy BUGFIX: ppO2 is displayed in Bailout mode New in 1.50 Stable: Initial release for OSTC Mk.2