Mercurial > public > mk2
diff code_part1/OSTC_code_asm_part1/menu_reset.asm @ 255:1efd59d689f8
small change in the set time menu, default setpoints set to 0.8, 1.0 and 1.2Bar
author | heinrichsweikamp |
---|---|
date | Sun, 10 Apr 2011 09:17:20 +0200 |
parents | 85ea09d3b9d8 |
children | ab1678d98e46 |
line wrap: on
line diff
--- a/code_part1/OSTC_code_asm_part1/menu_reset.asm Fri Apr 08 11:58:55 2011 +0200 +++ b/code_part1/OSTC_code_asm_part1/menu_reset.asm Sun Apr 10 09:17:20 2011 +0200 @@ -364,11 +364,15 @@ clrf EEDATA write_int_eeprom d'32' ; reset change depth gas #5 + movlw d'80' + movwf EEDATA + write_int_eeprom d'36' ; reset mix1 to ppO2=0.80Bar movlw d'100' movwf EEDATA - write_int_eeprom d'36' ; reset mix1 to ppO2=1.00Bar write_int_eeprom d'37' ; reset mix2 to ppO2=1.00Bar - write_int_eeprom d'38' ; reset mix3 to ppO2=1.00Bar + movlw d'120' + movwf EEDATA + write_int_eeprom d'38' ; reset mix3 to ppO2=1.20Bar clrf nofly_time+0 ; Clear nofly time clrf nofly_time+1 ; Clear nofly time