diff code_part1/OSTC_code_asm_part1/menu_reset.asm @ 255:1efd59d689f8

small change in the set time menu, default setpoints set to 0.8, 1.0 and 1.2Bar
author heinrichsweikamp
date Sun, 10 Apr 2011 09:17:20 +0200
parents 85ea09d3b9d8
children ab1678d98e46
line wrap: on
line diff
--- a/code_part1/OSTC_code_asm_part1/menu_reset.asm	Fri Apr 08 11:58:55 2011 +0200
+++ b/code_part1/OSTC_code_asm_part1/menu_reset.asm	Sun Apr 10 09:17:20 2011 +0200
@@ -364,11 +364,15 @@
 	clrf	EEDATA
 	write_int_eeprom	d'32'		; reset change depth gas #5
 
+	movlw	d'80'
+	movwf	EEDATA
+	write_int_eeprom	d'36'		; reset mix1 to ppO2=0.80Bar
 	movlw	d'100'
 	movwf	EEDATA
-	write_int_eeprom	d'36'		; reset mix1 to ppO2=1.00Bar
 	write_int_eeprom	d'37'		; reset mix2 to ppO2=1.00Bar
-	write_int_eeprom	d'38'		; reset mix3 to ppO2=1.00Bar
+	movlw	d'120'
+	movwf	EEDATA
+	write_int_eeprom	d'38'		; reset mix3 to ppO2=1.20Bar
 
 	clrf	nofly_time+0			; Clear nofly time
 	clrf	nofly_time+1			; Clear nofly time