Tue, 22 Aug 2017 13:23:52 +0200 |
heinrichsweikamp |
NEW: Show a warning for each sensor if the sensor is end-of-life after calibration (Less then 8mV in Air at sea level)
|
Mon, 21 Aug 2017 14:55:36 +0200 |
heinrichsweikamp |
CHANGE: CCR Calibration gas range limited to O2% 21-25 and 95-100 to save button presses
|
Thu, 17 Aug 2017 13:20:03 +0200 |
heinrichsweikamp |
2.20beta release
|
Sun, 06 Aug 2017 20:12:49 +0200 |
heinrichsweikamp |
BUGFIX: Ignore "Toggle GF" Menu entry (in divemode) when using the non-GF deco mode
|
Sat, 05 Aug 2017 17:36:58 +0200 |
heinrichsweikamp |
BUGFIX: O2 as diluent in CCR caused wrong calculations (Deco, EAD, END) in less then 6m depth
|
Sat, 05 Aug 2017 16:50:28 +0200 |
heinrichsweikamp |
BUGFIX: Skip MOD Test for CCR in Sensor modes (OSTC cR and OSTC3 only)
|
Sat, 05 Aug 2017 15:04:08 +0200 |
heinrichsweikamp |
BUGFIX: Do not show GF in divemode for non-GF deco mode
|
Fri, 04 Aug 2017 19:20:58 +0200 |
heinrichsweikamp |
BUGFIX: Menu tree cleaned up (Exited to CCR menu from simulator settings)
|
Fri, 04 Aug 2017 16:19:50 +0200 |
heinrichsweikamp |
BUGFIX: Impossible fixed-ppO2 (e.g. 1,6bar in 3m) used for tissue calculations
|
Fri, 04 Aug 2017 16:01:28 +0200 |
heinrichsweikamp |
CHANGE: Apply safety margin parameters to both models (GF and non-GF)
|
Thu, 03 Aug 2017 17:17:25 +0200 |
heinrichsweikamp |
BUGFIX: Do not check ppO2 for disabled gases
|
Thu, 03 Aug 2017 17:03:05 +0200 |
heinrichsweikamp |
CHANGE: Show actual GF (Not relative) in custom views in dive mode
|
Thu, 03 Aug 2017 16:59:31 +0200 |
heinrichsweikamp |
NEW: ppO2 blinks in sensor mode when min/max boundaries are hit
|
Tue, 04 Jul 2017 16:12:53 +0200 |
heinrichsweikamp |
BUGFIX: Lost Diluent now possible in CCR and PSCR mode
|