log src/changelog.txt @ 552:af84c45429fd

age author description
Sun, 19 Nov 2017 17:22:11 +0100 heinrichsweikamp BUGFIX: Display of negative (?C) water temperatures
Thu, 07 Sep 2017 14:25:22 +0200 heinrichsweikamp 2.25 stable RC
Fri, 01 Sep 2017 13:18:38 +0200 heinrichsweikamp 2.23beta release
Tue, 22 Aug 2017 13:23:52 +0200 heinrichsweikamp NEW: Show a warning for each sensor if the sensor is end-of-life after calibration (Less then 8mV in Air at sea level)
Mon, 21 Aug 2017 14:55:36 +0200 heinrichsweikamp CHANGE: CCR Calibration gas range limited to O2% 21-25 and 95-100 to save button presses
Thu, 17 Aug 2017 13:20:03 +0200 heinrichsweikamp 2.20beta release
Sun, 06 Aug 2017 20:12:49 +0200 heinrichsweikamp BUGFIX: Ignore "Toggle GF" Menu entry (in divemode) when using the non-GF deco mode
Sat, 05 Aug 2017 17:36:58 +0200 heinrichsweikamp BUGFIX: O2 as diluent in CCR caused wrong calculations (Deco, EAD, END) in less then 6m depth
Sat, 05 Aug 2017 16:50:28 +0200 heinrichsweikamp BUGFIX: Skip MOD Test for CCR in Sensor modes (OSTC cR and OSTC3 only)
Sat, 05 Aug 2017 15:04:08 +0200 heinrichsweikamp BUGFIX: Do not show GF in divemode for non-GF deco mode
Fri, 04 Aug 2017 19:20:58 +0200 heinrichsweikamp BUGFIX: Menu tree cleaned up (Exited to CCR menu from simulator settings)
Fri, 04 Aug 2017 16:19:50 +0200 heinrichsweikamp BUGFIX: Impossible fixed-ppO2 (e.g. 1,6bar in 3m) used for tissue calculations
Fri, 04 Aug 2017 16:01:28 +0200 heinrichsweikamp CHANGE: Apply safety margin parameters to both models (GF and non-GF)
Thu, 03 Aug 2017 17:17:25 +0200 heinrichsweikamp BUGFIX: Do not check ppO2 for disabled gases
Thu, 03 Aug 2017 17:03:05 +0200 heinrichsweikamp CHANGE: Show actual GF (Not relative) in custom views in dive mode
Thu, 03 Aug 2017 16:59:31 +0200 heinrichsweikamp NEW: ppO2 blinks in sensor mode when min/max boundaries are hit
Tue, 04 Jul 2017 16:12:53 +0200 heinrichsweikamp BUGFIX: Lost Diluent now possible in CCR and PSCR mode
Thu, 29 Jun 2017 11:48:13 +0200 heinrichsweikamp 2.20 RC1
Thu, 29 Jun 2017 11:47:08 +0200 heinrichsweikamp 2.18 beta release
Tue, 27 Jun 2017 13:50:42 +0200 heinrichsweikamp NEW: Two ppO2 max settings. One for travel/bottom and one for deco gases
Mon, 26 Jun 2017 13:02:04 +0200 heinrichsweikamp BUGFIX: PSCR mode "Better Gas" showed bailout gases instead of diluents
Mon, 26 Jun 2017 12:30:54 +0200 heinrichsweikamp BUGFIX: Reset to MOD in Diluent Menu did reset Setpoint change depth
Sun, 11 Jun 2017 17:11:40 +0200 heinrichsweikamp NEW: Last Dive customviews in surface mode with divetime, depth and interval
Fri, 09 Jun 2017 14:47:02 +0200 heinrichsweikamp BUGFIX: PSCR mode showed bailout gaslist instead of diluent gaslist
Thu, 11 May 2017 15:39:40 +0200 heinrichsweikamp Battery % in logbook when updated from Sport to Tech
Mon, 08 May 2017 12:52:49 +0200 heinrichsweikamp minor
Thu, 30 Mar 2017 11:28:40 +0200 heinrichsweikamp 2.15 rc
Wed, 29 Mar 2017 21:35:12 +0200 heinrichsweikamp NEW: Deep Sleep mode for OSTC Plus and OSTC 2 (2017) (Entered automatically)
Mon, 20 Feb 2017 15:51:51 +0100 heinrichsweikamp 2.15 start...
Mon, 06 Feb 2017 16:26:36 +0100 heinrichsweikamp NEW: PSCR mode (Passive semi-closed rebreather)
Wed, 01 Feb 2017 13:51:59 +0100 heinrichsweikamp BUGFIX: Layout fixes in Gauge mode (German and French language only)
Mon, 16 Jan 2017 11:59:55 +0100 heinrichsweikamp NEW: Show battery type in surface mode next to battery voltage
Sun, 18 Dec 2016 18:20:39 +0100 heinrichsweikamp CHANGE: Show warnings either in Customview (If active) _or_ next to warning sign
Sun, 11 Dec 2016 14:43:56 +0100 heinrichsweikamp NEW: New Customview 11 in dive mode shows ppO2, EAD/END and CNS
Fri, 18 Nov 2016 10:49:32 +0100 heinrichsweikamp BUGFIX: Minor layout corrections in imperial units dive screen
Wed, 02 Nov 2016 15:46:22 +0100 heinrichsweikamp CHANGE: Easier to understand "New Battery" menu (OSTC model dependent)
Fri, 28 Oct 2016 11:30:50 +0200 heinrichsweikamp CHANGE: Indicate "Bailout" for bailout deco plan in internal deco planer
Mon, 10 Oct 2016 10:59:19 +0200 heinrichsweikamp 2.10 release
Tue, 27 Sep 2016 16:40:14 +0200 heinrichsweikamp NEW: Store more battery info into logbook memory
Mon, 19 Sep 2016 16:32:02 +0200 heinrichsweikamp NEW: Show Uptime (Time since last firmware boot) in information menu
Thu, 01 Sep 2016 13:28:15 +0200 heinrichsweikamp changelog
Tue, 30 Aug 2016 17:26:21 +0200 heinrichsweikamp work on new battery options
Wed, 17 Aug 2016 09:50:37 +0200 heinrichsweikamp Adjustable timeout for Divemode (Config 0x48)
Tue, 26 Jul 2016 12:08:29 +0200 heinrichsweikamp +BUGFIX: Compatibility with "hwOS Config" fixed
Thu, 30 Jun 2016 10:28:12 +0200 heinrichsweikamp CHANGE: Language fixes, 2.08 release
Thu, 23 Jun 2016 10:59:42 +0200 heinrichsweikamp Logbook marker temporally disabled in internal logbook
Thu, 12 May 2016 14:58:32 +0200 heinrichsweikamp ignore 0x47 for standard hwOS
Mon, 25 Apr 2016 15:25:32 +0200 heinrichsweikamp CHANGE: Remove ppO2 [Dil] from OC dive mode screen
Mon, 18 Apr 2016 14:34:57 +0200 heinrichsweikamp NEW: Support for new logbook memory chip (minor hardware change)
Tue, 22 Mar 2016 16:39:00 +0100 heinrichsweikamp NEW: New Customview shows ppO2(O2) and ppO2(Diluent) during CCR mode
Fri, 11 Mar 2016 10:11:07 +0100 heinrichsweikamp BUGFIX: Fix missing ccr setup menu (From 2.02)
Tue, 08 Mar 2016 11:42:58 +0100 heinrichsweikamp BUGFIX: Fix rare issue after battery change (OSTC3 did not start properly)
Tue, 02 Feb 2016 11:09:14 +0100 heinrichsweikamp 2.01 release
Tue, 02 Feb 2016 10:40:52 +0100 heinrichsweikamp changelog
Mon, 01 Feb 2016 20:44:01 +0100 heinrichsweikamp BUGFIX: Divetime >99mins was not displayed (Only OSTC2 with serial >= )
Sun, 10 Jan 2016 11:24:33 +0100 heinrichsweikamp NEW: "Lost Gas" feature allows disabling gases during the dive