log tools/dev_ostc3_firmware.hex @ 543:a92cecf8cee4

age author description
Wed, 06 Sep 2017 11:08:59 +0200 heinrichsweikamp BUGFIX: "lost gas" showed current set of gases (Diluents in CC, OC in Bailout) for both "lost gas" menus
Tue, 05 Sep 2017 15:32:51 +0200 heinrichsweikamp minor simulator fix
Fri, 01 Sep 2017 13:18:38 +0200 heinrichsweikamp 2.23beta release
Mon, 28 Aug 2017 18:45:45 +0200 heinrichsweikamp Re-insert Rev. 530 changes into gaslist.asm
Fri, 25 Aug 2017 11:07:52 +0200 heinrichsweikamp 2.22 internal release
Tue, 22 Aug 2017 15:14:06 +0200 heinrichsweikamp update customview mask to (eventually) rewrite ppO2(Dil): to ppO2:
Tue, 22 Aug 2017 13:23:52 +0200 heinrichsweikamp NEW: Show a warning for each sensor if the sensor is end-of-life after calibration (Less then 8mV in Air at sea level)
Mon, 21 Aug 2017 15:11:06 +0200 heinrichsweikamp Setpoint Change Depth Fix
Mon, 21 Aug 2017 14:55:36 +0200 heinrichsweikamp CHANGE: CCR Calibration gas range limited to O2% 21-25 and 95-100 to save button presses
Mon, 21 Aug 2017 14:25:02 +0200 heinrichsweikamp Minor French text update, roll-back gaslist.asm changes
Thu, 17 Aug 2017 13:20:03 +0200 heinrichsweikamp 2.20beta release
Sun, 06 Aug 2017 20:12:49 +0200 heinrichsweikamp BUGFIX: Ignore "Toggle GF" Menu entry (in divemode) when using the non-GF deco mode
Sat, 05 Aug 2017 17:36:58 +0200 heinrichsweikamp BUGFIX: O2 as diluent in CCR caused wrong calculations (Deco, EAD, END) in less then 6m depth
Sat, 05 Aug 2017 16:50:28 +0200 heinrichsweikamp BUGFIX: Skip MOD Test for CCR in Sensor modes (OSTC cR and OSTC3 only)
Sat, 05 Aug 2017 15:04:08 +0200 heinrichsweikamp BUGFIX: Do not show GF in divemode for non-GF deco mode
Sat, 05 Aug 2017 10:58:40 +0200 heinrichsweikamp menu work
Fri, 04 Aug 2017 19:20:58 +0200 heinrichsweikamp BUGFIX: Menu tree cleaned up (Exited to CCR menu from simulator settings)
Fri, 04 Aug 2017 16:19:50 +0200 heinrichsweikamp BUGFIX: Impossible fixed-ppO2 (e.g. 1,6bar in 3m) used for tissue calculations
Fri, 04 Aug 2017 16:01:28 +0200 heinrichsweikamp CHANGE: Apply safety margin parameters to both models (GF and non-GF)
Thu, 03 Aug 2017 17:03:05 +0200 heinrichsweikamp CHANGE: Show actual GF (Not relative) in custom views in dive mode
Thu, 03 Aug 2017 16:59:31 +0200 heinrichsweikamp NEW: ppO2 blinks in sensor mode when min/max boundaries are hit
Sat, 15 Jul 2017 10:38:35 +0200 heinrichsweikamp hex build
Tue, 04 Jul 2017 16:12:53 +0200 heinrichsweikamp BUGFIX: Lost Diluent now possible in CCR and PSCR mode
Fri, 30 Jun 2017 15:12:56 +0200 heinrichsweikamp BUGFIX: Planner in CCR mode used OC gases for volume calculations in some cases