Fri, 01 Sep 2017 13:18:38 +0200 heinrichsweikamp 2.23beta release
Tue, 22 Aug 2017 13:23:52 +0200 heinrichsweikamp NEW: Show a warning for each sensor if the sensor is end-of-life after calibration (Less then 8mV in Air at sea level)
Mon, 21 Aug 2017 14:55:36 +0200 heinrichsweikamp CHANGE: CCR Calibration gas range limited to O2% 21-25 and 95-100 to save button presses
Thu, 17 Aug 2017 13:20:03 +0200 heinrichsweikamp 2.20beta release
Sun, 06 Aug 2017 20:12:49 +0200 heinrichsweikamp BUGFIX: Ignore "Toggle GF" Menu entry (in divemode) when using the non-GF deco mode
Sat, 05 Aug 2017 17:36:58 +0200 heinrichsweikamp BUGFIX: O2 as diluent in CCR caused wrong calculations (Deco, EAD, END) in less then 6m depth
Sat, 05 Aug 2017 16:50:28 +0200 heinrichsweikamp BUGFIX: Skip MOD Test for CCR in Sensor modes (OSTC cR and OSTC3 only)
Sat, 05 Aug 2017 15:04:08 +0200 heinrichsweikamp BUGFIX: Do not show GF in divemode for non-GF deco mode
Fri, 04 Aug 2017 19:20:58 +0200 heinrichsweikamp BUGFIX: Menu tree cleaned up (Exited to CCR menu from simulator settings)
Fri, 04 Aug 2017 16:19:50 +0200 heinrichsweikamp BUGFIX: Impossible fixed-ppO2 (e.g. 1,6bar in 3m) used for tissue calculations
Fri, 04 Aug 2017 16:01:28 +0200 heinrichsweikamp CHANGE: Apply safety margin parameters to both models (GF and non-GF)
Thu, 03 Aug 2017 17:17:25 +0200 heinrichsweikamp BUGFIX: Do not check ppO2 for disabled gases
Thu, 03 Aug 2017 17:03:05 +0200 heinrichsweikamp CHANGE: Show actual GF (Not relative) in custom views in dive mode
Thu, 03 Aug 2017 16:59:31 +0200 heinrichsweikamp NEW: ppO2 blinks in sensor mode when min/max boundaries are hit
Tue, 04 Jul 2017 16:12:53 +0200 heinrichsweikamp BUGFIX: Lost Diluent now possible in CCR and PSCR mode
Thu, 29 Jun 2017 11:48:13 +0200 heinrichsweikamp 2.20 RC1
Thu, 29 Jun 2017 11:47:08 +0200 heinrichsweikamp 2.18 beta release
Tue, 27 Jun 2017 13:50:42 +0200 heinrichsweikamp NEW: Two ppO2 max settings. One for travel/bottom and one for deco gases
Mon, 26 Jun 2017 13:02:04 +0200 heinrichsweikamp BUGFIX: PSCR mode "Better Gas" showed bailout gases instead of diluents
Mon, 26 Jun 2017 12:30:54 +0200 heinrichsweikamp BUGFIX: Reset to MOD in Diluent Menu did reset Setpoint change depth
Sun, 11 Jun 2017 17:11:40 +0200 heinrichsweikamp NEW: Last Dive customviews in surface mode with divetime, depth and interval
Fri, 09 Jun 2017 14:47:02 +0200 heinrichsweikamp BUGFIX: PSCR mode showed bailout gaslist instead of diluent gaslist
Thu, 11 May 2017 15:39:40 +0200 heinrichsweikamp Battery % in logbook when updated from Sport to Tech
Mon, 08 May 2017 12:52:49 +0200 heinrichsweikamp minor
Thu, 30 Mar 2017 11:28:40 +0200 heinrichsweikamp 2.15 rc
Wed, 29 Mar 2017 21:35:12 +0200 heinrichsweikamp NEW: Deep Sleep mode for OSTC Plus and OSTC 2 (2017) (Entered automatically)
Mon, 20 Feb 2017 15:51:51 +0100 heinrichsweikamp 2.15 start...
Mon, 06 Feb 2017 16:26:36 +0100 heinrichsweikamp NEW: PSCR mode (Passive semi-closed rebreather)
Wed, 01 Feb 2017 13:51:59 +0100 heinrichsweikamp BUGFIX: Layout fixes in Gauge mode (German and French language only)
Mon, 16 Jan 2017 11:59:55 +0100 heinrichsweikamp NEW: Show battery type in surface mode next to battery voltage