Fri, 04 Aug 2017 16:19:50 +0200 |
heinrichsweikamp |
BUGFIX: Impossible fixed-ppO2 (e.g. 1,6bar in 3m) used for tissue calculations
|
Fri, 04 Aug 2017 16:01:28 +0200 |
heinrichsweikamp |
CHANGE: Apply safety margin parameters to both models (GF and non-GF)
|
Thu, 03 Aug 2017 17:17:25 +0200 |
heinrichsweikamp |
BUGFIX: Do not check ppO2 for disabled gases
|
Thu, 03 Aug 2017 17:03:05 +0200 |
heinrichsweikamp |
CHANGE: Show actual GF (Not relative) in custom views in dive mode
|
Thu, 03 Aug 2017 16:59:31 +0200 |
heinrichsweikamp |
NEW: ppO2 blinks in sensor mode when min/max boundaries are hit
|
Tue, 04 Jul 2017 16:12:53 +0200 |
heinrichsweikamp |
BUGFIX: Lost Diluent now possible in CCR and PSCR mode
|
Thu, 29 Jun 2017 11:48:13 +0200 |
heinrichsweikamp |
2.20 RC1
|
Thu, 29 Jun 2017 11:47:08 +0200 |
heinrichsweikamp |
2.18 beta release
|
Tue, 27 Jun 2017 13:50:42 +0200 |
heinrichsweikamp |
NEW: Two ppO2 max settings. One for travel/bottom and one for deco gases
|
Mon, 26 Jun 2017 13:02:04 +0200 |
heinrichsweikamp |
BUGFIX: PSCR mode "Better Gas" showed bailout gases instead of diluents
|
Mon, 26 Jun 2017 12:30:54 +0200 |
heinrichsweikamp |
BUGFIX: Reset to MOD in Diluent Menu did reset Setpoint change depth
|
Sun, 11 Jun 2017 17:11:40 +0200 |
heinrichsweikamp |
NEW: Last Dive customviews in surface mode with divetime, depth and interval
|