log src/changelog.txt @ 526:0d1cda9f2d43

age author description
Sat, 05 Aug 2017 16:50:28 +0200 heinrichsweikamp BUGFIX: Skip MOD Test for CCR in Sensor modes (OSTC cR and OSTC3 only)
Sat, 05 Aug 2017 15:04:08 +0200 heinrichsweikamp BUGFIX: Do not show GF in divemode for non-GF deco mode
Fri, 04 Aug 2017 19:20:58 +0200 heinrichsweikamp BUGFIX: Menu tree cleaned up (Exited to CCR menu from simulator settings)
Fri, 04 Aug 2017 16:19:50 +0200 heinrichsweikamp BUGFIX: Impossible fixed-ppO2 (e.g. 1,6bar in 3m) used for tissue calculations
Fri, 04 Aug 2017 16:01:28 +0200 heinrichsweikamp CHANGE: Apply safety margin parameters to both models (GF and non-GF)
Thu, 03 Aug 2017 17:17:25 +0200 heinrichsweikamp BUGFIX: Do not check ppO2 for disabled gases
Thu, 03 Aug 2017 17:03:05 +0200 heinrichsweikamp CHANGE: Show actual GF (Not relative) in custom views in dive mode
Thu, 03 Aug 2017 16:59:31 +0200 heinrichsweikamp NEW: ppO2 blinks in sensor mode when min/max boundaries are hit
Tue, 04 Jul 2017 16:12:53 +0200 heinrichsweikamp BUGFIX: Lost Diluent now possible in CCR and PSCR mode
Thu, 29 Jun 2017 11:48:13 +0200 heinrichsweikamp 2.20 RC1
Thu, 29 Jun 2017 11:47:08 +0200 heinrichsweikamp 2.18 beta release
Tue, 27 Jun 2017 13:50:42 +0200 heinrichsweikamp NEW: Two ppO2 max settings. One for travel/bottom and one for deco gases