Mercurial > public > hwos_code
view src/changelog.txt @ 598:e1f0f5e3d4e4
BUGFIX: Internal deco planner did not display results in imperial units
author | heinrichsweikamp |
---|---|
date | Mon, 30 Jul 2018 19:45:53 +0200 |
parents | b891cd260d1b |
children | ab88a7e3de94 |
line wrap: on
line source
[2.97 SP2] - Stable Version - BUGFIX: "lost gas" was re-activated in rare cases BUGFIX: Internal deco planner did not display results in imperial units [2.97 SP1] - Stable Version - BUGFIX: Re-enable Sensors after sleep in PSCR mode BUGFIX: handle two deco gases configured to the same change depth CHANGE: minor italian translation update CHANGE: Sync safety stop countdown output with divetime [2.97] - Stable Version - NEW: On-the-fly Gas needs calculations for all active gases NEW: Internal deco calculator shows deco plan and gas beeds for Bailout case NEW: CNS now, CNS in xx minutes, CNS if bailout plan is used and CNS when surfaced (Including all deco stops) is shown NEW: Bailout TTS is computed in CCR mode (optionally) with gas needs for all bailout gases and all deco stops NEW: Warning if an isobaric counter diffusion occurs (also in internal planner) NEW: Warning "X-ZHL16-X" if deco model is used beyond theoretical limits NEW: Show "Deco Zone" if we are in deco and at least one tissue is off-gassing CHANGE: Internal deco routines heavily optimised for speed and code size CHANGE: Limit button sensitivity to 80% BUGFIX: Auto-Gain for newer compass versions did not work (Which decreased accuracy of heading) CHANGE: Make disabled gases darker in surface mode (Common issue for color-blind divers) CHANGE: French and Italien language updates NEW: Independent saturation/desaturation multipliers for GF and non-GF Deco modes CHANGE: Non-updated values are shown in dark blue (e.g. after a gas change) until values are valid again CHANGE: USB OSTC (OSTC 3 and OSTC cR) will enter USB mode from Menu only [2.27] - Beta Version - BUGFIX: Display of negative (°C) water temperatures NEW: Display dezimal for temperatures between 10 and 0°C [2.25] - Stable Version - BUGFIX: "lost gas" showed current set of gases (Diluents in CC, OC in Bailout) for both "lost gas" menus NEW: Show Compass calibration results in Compass menu BUGFIX: Simulator in CC mode BUGFIX: Changing the dive mode and starting the simulator (without leaving the menu first) caused false calculations in the simulator BUGFIX: PSCR Mode "OC Gases" showed Diluents, not OC gases BUGFIX: CCR Mode ("First Diluent") was chosen based on OC "First Gas" number [2.23] - Beta Version - CHANGE: CCR Calibration gas range limited to O2% 21-25 and 95-100 to save button presses NEW: Show a warning for each sensor if the sensor is end-of-life after calibration (Less then 8mV in Air at sea level) CHANGE: Minor optimizations [2.20] - Beta Version - BUGFIX: Lost Diluent now possible in CCR and PSCR mode NEW: ppO2 blinks in sensor mode when min/max boundaries are hit CHANGE: Show actual GF (Not relative) in custom views in dive mode BUGFIX: Do not check ppO2 for disabled gases CHANGE: Apply safety margin parameters to both models (GF and non-GF) BUGFIX: Impossible fixed-ppO2 (e.g. 1,6bar in 3m) used for tissue calculations BUGFIX: Menu tree cleaned up (Exited to CCR menu from simulator settings) BUGFIX: Do not show GF in divemode for non-GF deco mode BUGFIX: Skip MOD Test for CCR in Sensor modes (OSTC cR and OSTC3 only) CHANGE: Swap positions of ppO2(O2) and ppO2(Dil) in customview 10 on screen: "left = lean" and "right = rich" BUGFIX: A wrong configured gas was suggested as "Better gas" on the configured depth even if this resulted in a ppO2 high or low condition BUGFIX: O2 as diluent in CCR caused wrong calculations (Deco, EAD, END) in less then 6m depth BUGFIX: Ignore "Toggle GF" Menu entry (in divemode) when using the non-GF deco mode BUGFIX: Minor dive mode layout fixes in CCR Mode CHANGE: Minor German language fixes NEW: Warning for Diluent beeing out of safe ppO2 range in CCR modes NEW: New Customview 9 in OSTC cR or OSTC3 shows mV readings after Sensor calibration [2.18] - Beta Version - NEW: Third and fourth logbook page per dive showing Gaslist and Setpoints in standard font size BUGFIX: several minor graphic issues in logbook fixed BUGFIX: Rare button issues in OSTC Plus hardware BUGFIX: Compass sensitivity for newer models BUGFIX: PSCR mode showed bailout gaslist instead of diluent gaslist BUGFIX: PSCR mode "Better Gas" showed bailout gases instead of diluents NEW: More customviews in surface mode for PSCR mode NEW: Last Dive customviews in surface mode with divetime, depth and interval BUGFIX: Reset to MOD in Diluent Menu did reset Setpoint change depth NEW: Two ppO2 max settings. One for travel/bottom and one for deco gases [2.15] - Stable Version - NEW: Deep Sleep mode for OSTC Plus and OSTC 2 (2017) (Entered automatically) NEW: Logbook detail page in larger font (And nicer layout) CHANGE: Sleep mode current slightly reduced for all hwOS devices NEW: Logbook now records battery information NEW: Markers in internal logbook drawn as small "m" next to the profile [2.14] - BETA Version - NEW: PSCR mode (Passive semi-closed rebreather) [2.13] - Stable Version - BUGFIX: Layout fixes in Gauge mode (German and French language only) [2.12] - Stable Version - CHANGE: Indicate "Bailout" for bailout deco plan in internal deco planer CHANGE: Easier to understand "New Battery" menu (OSTC model dependent) BUGFIX: Minor layout corrections in imperial units dive screen NEW: New Customview 11 in dive mode shows ppO2, EAD/END and CNS CHANGE: Customview 4 shows Clock, Battery Information and Tissue Information CHANGE: Show warnings either in Customview (If active) _or_ next to warning sign NEW: Show battery type in information menu (T0:1.5V AA, T1:3.6V AA, T2:3.6V/0.8A LiIon, T3:Internal 18650, T4:Internal 16650) NEW: Show battery type in surface mode next to battery voltage [2.10] - Stable Version - NEW: Adjustable timeout for Divemode CHANGE: Firmware now split in two variants (EN/DE) and (FR/IT) NEW: New battery option for AA 3,7V rechargable (For OSTC 3) NEW: Show Uptime (Time since last firmware boot) in information menu NEW: Store more battery info into logbook memory BUGFIX: Minor text alignment fixes [2.09] - Stable Version - BUGFIX: Compatibility with "hwOS Config" fixed NEW: New hardware descriptor command 0x60 added (For PC programs) [2.08] - Stable Version - CHANGE: Logbook marker temporally disabled in internal logbook BUGFIX: Characters with descenders were not drawn correctly in rare cases NEW: Support for different compass chip (Internal hardware change) CHANGE: Language fixes [2.07] - Stable Version - Release version for new OSTC2 (Minor internal hardware changes) [2.06] CHANGE: Remove ppO2 [Dil] from OC dive mode screen [2.05] NEW: Support for new logbook memory chip (minor hardware change) BUGFIX: Button sensitivity was not reset after update in some cases [2.04] - Beta Version - NEW: New Customview shows ppO2(O2) and ppO2(Diluent) during CCR mode [2.03] - Stable Version - BUGFIX: Fix missing ccr setup menu (From 2.02) [2.02] - Stable Version - BUGFIX: Fix rare issue after battery change (OSTC3 did not start properly) [2.01] - Stable Version - BUGFIX: Divetime >99mins was not displayed (Only OSTC2 with serial > 10500) BUGFIX: Minor layout fixes in divemode (Dynamic gaslist and stopwatch) BUGFIX: Minor language updates [2.00] - Stable Version - NEW: Logbook marker can be set in dive mode menu (OC only) NEW: Logbook shows markers with small orange boxes in the profile NEW: "Lost Gas" feature allows disabling gases during the dive [1.94] - Beta Version - CHANGE: Show velocity from 5m/min or more (Ascend or descent) BUGFIX: Make sure SP1 is always selected on start in Auto-SP mode CHANGE: New segmented speed graph in divemode NEW: Safety Stop can be configured (Start-, End- and reset-depth + length of stop) via PC [1.93] - Stable Version - BUGFIX: minor text allignment in CCR mode CHANGE: fix timing issues during Bluetooth download (Bluetooth models only) [1.92] - Stable Version - CHANGE: Logbook now shows end-of-dive date and time for dives made with firmware <1.92 indicated by an icon in the logbook CHANGE: Logbook shows start-of-dive date and time for dives made with firmware >=1.92 BUGFIX: Text alignment in logbook NEW: Show actual dive count in logbook list view (If <1000) BUGFIX: Minor language and text aligment fixes [1.91] - Stable Version - BUGFIX: German texts in ppo2 menu were too long for screen resulting in resulting in text display issues [1.90] - Stable Version - CHANGE: Do not show ppO2 in warning area if already shown in custom view BUGFIX: Logbook list view for more then 100 stored dives BUGFIX: BLE timings for MAC issues BUGFIX: Battery consumption calculation in sleep mode (3,6V battery only) NEW: Bearing can be set in surface mode BUGFIX: +5min for stopwatch during simulation did not work CHANGE: minor language updates [1.88] - Stable Version - BUGFIX: Start with Sensor use from sleep (cR only) CHANGE: Apply button settings when button menu is closed NEW: Reset button settings on a magnet reset (cR and OSTC 2) [1.87] - Stable Version - NEW: Additional temperature calibration via PC interface NEW: Hardware support (Screen) [1.86] - Stable Version - [1.85] - Beta Version - BUGFIX: Rotate button sensitivity with screen (OSTC 2 and cR) CHANGE: GF and aGF high range increased to 45-110% NEW: New option to download "Compact Headers". Improved BLE support (OSTC 2 and OSTC 3+) NEW: Quit Simulator automatically when starting a real dive BUGFIX: Auto-Brightness clipped to lowest settings in bright sunlight on some devices CHANGE: Auto SP now available on OSTC 2 [1.82] - Beta Version - CHANGE: change button sensitivity range and default (OSTC2 and cR) NEW: MOD Warning (Can be disabled) NEW: Depth dependent ascend speed (Can be disabled) NEW: Graphical speed indicator (Can be disabled) NEW: Option to always show the ppO2, shows ppO2 for Diluent in CC mode NEW: Mode Auto SP: Automatically switches the SP during descent (CC Mode) NEW: Deco planer computes gas consumption for all gases and can compute bailout plans for CC modes [1.81] - Stable Version - BUGFIX: Fix download issue for dives made with 1.80 firmware [1.80] - Stable Version - CHANGE: Automatically abort connection fail after 2mins (Bluetooth only) BUGFIX: Fast Gas change near the ppO2 limit could cause switching to a non-available Gas #0 CHANGE: Code now called hwOS officially BUGFIX: There was a 1:4096 chance that a portion of a dive was not stored correctly resulting in download issues [1.78] - Stable Version - BUGFIX: Increase timing tolerance for S8 HUD (cR only) CHANGE: increase min input voltage from 1,2mV to 1,9mV (cR only) CHANGE: adjust menu for different hardware versions (OSTC 2) [1.77] - Stable Version - BUGFIX: Charge done indicator (cR and 2 Hardware) BUGFIX: Analog sensors were ignored in 1.76 [1.76] - Stable Version - CHANGE: aGF pair has same range then normal GF pair BUGFIX: Always update CCR sensor data in Sensor-Menu NEW: Graphical compass display in dive mode NEW: Bearing option in divemode CHANGE: New warning icon [1.75] - Stable Version - BUGFIX: Show average depth with one dezimal digit only NEW: Show start gas in OC mode permanently NEW: Show OSTC2-like active gas boxes in surface mode [1.74] - Stable Version - BUGFIX: Show dives with >999mins divetime correctly NEW: Support for optical hwHUD without the LED module (OSTC3 only) [1.72] - Stable Version - BUGFIX: Store new dives after power-loss during divemode correctly NEW: Make button sensitivity configurable (cR hardware) [1.70] - Stable Version - NEW: Show plan parameters in decoplan result page NEW: On-board simulator can increase divetime in 5min steps BUGFIX: Layout fixes [1.62] - Beta Version - CHANGE: (Slightly) reduce current consumption in Eco and sleep mode NEW: Allow auto-return from setpoint fallback [1.61] - Beta Version - BUGFIX: O2 > 99% was not configurable from the PC BUGFIX: Quit Apnea mode on the surface manually BUGFIX: Check min and max values after PC configuration properly CHANGE: Longer timeout (4 min) for calibration menu and Surface mode (CCR Modes) NEW: Show Bailout Gas List in Surface mode (CCR Modes) CHANGE: Faster update rate for sensor display in surface mode [1.60] - Stable Version - BUGFIX: END/EAD updated when adjusting current gas during the dive [1.54] - Beta Version - BUGFIX: Future TTS in sensor mode (CCR Mode) CHANGE: Clarify Travel Gases with "---" as change depth CHANGE: Enable "Change Depth" Menu only for deco gases CHANGE: Draw a frame around the dive mode menu BUGFIX: Average depth computation [1.53] - Beta Version - BUGFIX: Flip compass with flipped screen, too BUGFIX: Surface interval was paused during simulator BUGFIX: False max. temp in Logbook, false Bailout and Gas 6 flags in logbook CHANGE: Improve internal logbook usability CHANGE: Compass readout smoothed [1.52] - Beta Version - NEW: Safe tissue data, date and time during firmware update CHANGE: Postion of min. and (NEW:) max. temperature in logbook BUGFIX: Fast diluent (w/o dive mode menu) change did not work correctly [1.51] - Beta Version - BUGFIX: Clear Setpoint-Fallback warning when in bailout NEW: 180° display rotation option NEW: Show ppO2 for change depth during gas setup CHANGE: Re-arranged Settings Menu BUGFIX: PC configuration issues fixed [1.50] Stable release [1.46] - Beta Version - NEW: Setpoint-Fallback option for external O2 sensor failure [1.45] - Beta Version - CHANGE: Minor German language update BUGFIX: Clock setting (Bug from 1.44beta) [1.44] - Beta Version - NEW: Update warnings every second NEW: Show "Stop" in front of Safety Stop BUGFIX: Start dive mode simulator in correct depth BUGFIX: Surface interval was not displayed correctly in some cases NEW: Store tissue load, date and time, surface interval, desat. time and nofly time every hour and reload them after battery change NEW: Show clock in Apnea mode, minor layout changes in Apnea mode NEW: Simplify gas change (Two button presses only) [1.41] - Beta Version - NEW: Ceiling display (GF_hi based) in divemode NEW: Support for C3 hardware CHANGE: Show heading with leading zeros BUGFIX: Do not show "GF info" for non-GF modes BUGFIX: Minor display allignment changes [1.40] CHANGE: Minor language updates NEW: Show a Safety Stop if enabled (Menu "Deco Parameters") BUGFIX: dive profile recording issue in OC mode BUGFIX: OSTC settings via USB issues BUGFIX: CNS in deco planner [1.30] NEW: Show event "Bailout" in internal logbook CHANGE: Always compute bailout plan based on all active gases CHANGE: Re-select last diluent when returning from bailout to OC BUGFIX: Show "*" always in front of the initial Setpoint 1 [1.26] BUGFIX: compass calibration does now timeout automatically after 60s BUGFIX: decoplan re-calculation in bailout case [1.25] BUGFIX: No average depth for end-of-dive portion (<1m) BUGFIX: Show "CC Diluents" in logbook instead of OC Gas List NEW: automatic compass gain makes calibration quicker CHANGE: Battery percent setpoints adjusted to worst case current consumption [1.24] CHANGE: Minor french translation CHANGE: No warning sign for selected aGF CHANGE: Show battery warning sign for less then 10% battery capacity only CHANGE: Color schemes improved [1.23] BUGFIX: Reset Logbook did not reset Logbook TOC properly [1.22] BUGFIX: Potential bug to freeze the OSTC3 after battery change or update [1.21] CHANGE: French Translations, again BUGFIX: Fix cursor in "New Battery" menu NEW: Show serial number and firmware version in main menu CHANGE: "Reset all" returns to surface mode CHANGE: Single press surfacemode menu [1.20] Stable release [1.12] BUGFIX: Maintain last selected customview in surface mode BUGFIX: Set Day for months <31 days CHANGE: Some French Translations CHANGE: Default Future TTS=0 (Disabled) NEW: Expand "gas change window" up to 1m below programmed change depth (If ppO2 within user-set max. threshold) BUGFIX: Intermittent USB connection on MAC [1.11] NEW: allow logbook erase from reset menu NEW: show battery voltage in info menu [1.10] Stable release [1.04] NEW: 1.6 hardware support CHANGE: Backlight level in eco mode BUGFIX: Display Desat.-Time >100 hours [1.03] NEW: user-selectable color schemes BUGFIX: div. language corrections NEW: Dynamic Gaslist in OC mode (Divemode, Customview 7) CHANGE: Change "O2" warning to "ppO2" NEW: "End-of-Dive" countdown when surfaced [1.02] CHANGE: Time and Date in normal (Not tiny) font BUGFIX: Minor french language fix [1.01] BUGFIX: deco gas init in OC planner [1.00] BUGFIX: Percent display with 1,5V batteries [0.99] BUGFIX: alternating brightness at very low ambient light CHANGE: GF high lowest setting 60% BUGFIX: NOAA tables for CNS are in ATA, not bar CHANGE: change apnea timeout, do no longer store apnea dives in logbook BUGFIX: Simulator in CC mode BUGFIX: Apnea total divetime BUGFIX: Battery percent value with 3,6V battery NEW: Surface customview with important deco settings [0.98] New: Add cardinal (and ordinal) directions for the compass [0.97] NEW: compass gain option to work with more magnetic battery types BUGFIX: fix imperial units in logbook [0.96] NEW: calm compass reading for minor heading changes NEW: reduce eco low brightness threshold (for cave diving) [0.95] BUGFIX: Show "MOD:" instead of "EAD:" in gas setup [0.94] CHANGE: Show Max. Depth with 0.1m precision [0.91] BUGFIX: Battery percents in cold water [0.93] BUGFIX: Custom text <60 chars BUGFIX: Logbook PC protocol Italian language updates BUGFIX: Timeout in decoplanner result page