Mercurial > public > hwos_code
view src/changelog.txt @ 365:d0e3fa3ff2e2
minor
author | heinrichsweikamp |
---|---|
date | Wed, 12 Aug 2015 17:41:06 +0200 |
parents | 7532d4e42f62 |
children | 57e349960ef4 |
line wrap: on
line source
[1.86] - Stable Version - [1.85] - Beta Version - BUGFIX: Rotate button sensitivity with screen (OSTC 2 and cR) CHANGE: GF and aGF high range increased to 45-110% NEW: New option to download "Compact Headers". Improved BLE support (OSTC 2 and OSTC 3+) NEW: Quit Simulator automatically when starting a real dive BUGFIX: Auto-Brightness clipped to lowest settings in bright sunlight on some devices CHANGE: Auto SP now available on OSTC 2 [1.82] - Beta Version - CHANGE: change button sensitivity range and default (OSTC2 and cR) NEW: MOD Warning (Can be disabled) NEW: Depth dependent ascend speed (Can be disabled) NEW: Graphical speed indicator (Can be disabled) NEW: Option to always show the ppO2, shows ppO2 for Diluent in CC mode NEW: Mode Auto SP: Automatically switches the SP during descent (CC Mode) NEW: Deco planer computes gas consumption for all gases and can compute bailout plans for CC modes [1.81] - Stable Version - BUGFIX: Fix download issue for dives made with 1.80 firmware [1.80] - Stable Version - CHANGE: Automatically abort connection fail after 2mins (Bluetooth only) BUGFIX: Fast Gas change near the ppO2 limit could cause switching to a non-available Gas #0 CHANGE: Code now called hwOS officially BUGFIX: There was a 1:4096 chance that a portion of a dive was not stored correctly resulting in download issues [1.78] - Stable Version - BUGFIX: Increase timing tolerance for S8 HUD (cR only) CHANGE: increase min input voltage from 1,2mV to 1,9mV (cR only) CHANGE: adjust menu for different hardware versions (OSTC 2) [1.77] - Stable Version - BUGFIX: Charge done indicator (cR and 2 Hardware) BUGFIX: Analog sensors were ignored in 1.76 [1.76] - Stable Version - CHANGE: aGF pair has same range then normal GF pair BUGFIX: Always update CCR sensor data in Sensor-Menu NEW: Graphical compass display in dive mode NEW: Bearing option in divemode CHANGE: New warning icon [1.75] - Stable Version - BUGFIX: Show average depth with one dezimal digit only NEW: Show start gas in OC mode permanently NEW: Show OSTC2-like active gas boxes in surface mode [1.74] - Stable Version - BUGFIX: Show dives with >999mins divetime correctly NEW: Support for optical hwHUD without the LED module (OSTC3 only) [1.72] - Stable Version - BUGFIX: Store new dives after power-loss during divemode correctly NEW: Make button sensitivity configurable (cR hardware) [1.70] - Stable Version - NEW: Show plan parameters in decoplan result page NEW: On-board simulator can increase divetime in 5min steps BUGFIX: Layout fixes [1.62] - Beta Version - CHANGE: (Slightly) reduce current consumption in Eco and sleep mode NEW: Allow auto-return from setpoint fallback [1.61] - Beta Version - BUGFIX: O2 > 99% was not configurable from the PC BUGFIX: Quit Apnea mode on the surface manually BUGFIX: Check min and max values after PC configuration properly CHANGE: Longer timeout (4 min) for calibration menu and Surface mode (CCR Modes) NEW: Show Bailout Gas List in Surface mode (CCR Modes) CHANGE: Faster update rate for sensor display in surface mode [1.60] - Stable Version - BUGFIX: END/EAD updated when adjusting current gas during the dive [1.54] - Beta Version - BUGFIX: Future TTS in sensor mode (CCR Mode) CHANGE: Clarify Travel Gases with "---" as change depth CHANGE: Enable "Change Depth" Menu only for deco gases CHANGE: Draw a frame around the dive mode menu BUGFIX: Average depth computation [1.53] - Beta Version - BUGFIX: Flip compass with flipped screen, too BUGFIX: Surface interval was paused during simulator BUGFIX: False max. temp in Logbook, false Bailout and Gas 6 flags in logbook CHANGE: Improve internal logbook usability CHANGE: Compass readout smoothed [1.52] - Beta Version - NEW: Safe tissue data, date and time during firmware update CHANGE: Postion of min. and (NEW:) max. temperature in logbook BUGFIX: Fast diluent (w/o dive mode menu) change did not work correctly [1.51] - Beta Version - BUGFIX: Clear Setpoint-Fallback warning when in bailout NEW: 180° display rotation option NEW: Show ppO2 for change depth during gas setup CHANGE: Re-arranged Settings Menu BUGFIX: PC configuration issues fixed [1.50] Stable release [1.46] - Beta Version - NEW: Setpoint-Fallback option for external O2 sensor failure [1.45] - Beta Version - CHANGE: Minor German language update BUGFIX: Clock setting (Bug from 1.44beta) [1.44] - Beta Version - NEW: Update warnings every second NEW: Show "Stop" in front of Safety Stop BUGFIX: Start dive mode simulator in correct depth BUGFIX: Surface interval was not displayed correctly in some cases NEW: Store tissue load, date and time, surface interval, desat. time and nofly time every hour and reload them after battery change NEW: Show clock in Apnea mode, minor layout changes in Apnea mode NEW: Simplify gas change (Two button presses only) [1.41] - Beta Version - NEW: Ceiling display (GF_hi based) in divemode NEW: Support for C3 hardware CHANGE: Show heading with leading zeros BUGFIX: Do not show "GF info" for non-GF modes BUGFIX: Minor display allignment changes [1.40] CHANGE: Minor language updates NEW: Show a Safety Stop if enabled (Menu "Deco Parameters") BUGFIX: dive profile recording issue in OC mode BUGFIX: OSTC settings via USB issues BUGFIX: CNS in deco planner [1.30] NEW: Show event "Bailout" in internal logbook CHANGE: Always compute bailout plan based on all active gases CHANGE: Re-select last diluent when returning from bailout to OC BUGFIX: Show "*" always in front of the initial Setpoint 1 [1.26] BUGFIX: compass calibration does now timeout automatically after 60s BUGFIX: decoplan re-calculation in bailout case [1.25] BUGFIX: No average depth for end-of-dive portion (<1m) BUGFIX: Show "CC Diluents" in logbook instead of OC Gas List NEW: automatic compass gain makes calibration quicker CHANGE: Battery percent setpoints adjusted to worst case current consumption [1.24] CHANGE: Minor french translation CHANGE: No warning sign for selected aGF CHANGE: Show battery warning sign for less then 10% battery capacity only CHANGE: Color schemes improved [1.23] BUGFIX: Reset Logbook did not reset Logbook TOC properly [1.22] BUGFIX: Potential bug to freeze the OSTC3 after battery change or update [1.21] CHANGE: French Translations, again BUGFIX: Fix cursor in "New Battery" menu NEW: Show serial number and firmware version in main menu CHANGE: "Reset all" returns to surface mode CHANGE: Single press surfacemode menu [1.20] Stable release [1.12] BUGFIX: Maintain last selected customview in surface mode BUGFIX: Set Day for months <31 days CHANGE: Some French Translations CHANGE: Default Future TTS=0 (Disabled) NEW: Expand "gas change window" up to 1m below programmed change depth (If ppO2 within user-set max. threshold) BUGFIX: Intermittent USB connection on MAC [1.11] NEW: allow logbook erase from reset menu NEW: show battery voltage in info menu [1.10] Stable release [1.04] NEW: 1.6 hardware support CHANGE: Backlight level in eco mode BUGFIX: Display Desat.-Time >100 hours [1.03] NEW: user-selectable color schemes BUGFIX: div. language corrections NEW: Dynamic Gaslist in OC mode (Divemode, Customview 7) CHANGE: Change "O2" warning to "ppO2" NEW: "End-of-Dive" countdown when surfaced [1.02] CHANGE: Time and Date in normal (Not tiny) font BUGFIX: Minor french language fix [1.01] BUGFIX: deco gas init in OC planner [1.00] BUGFIX: Percent display with 1,5V batteries [0.99] BUGFIX: alternating brightness at very low ambient light CHANGE: GF high lowest setting 60% BUGFIX: NOAA tables for CNS are in ATA, not bar CHANGE: change apnea timeout, do no longer store apnea dives in logbook BUGFIX: Simulator in CC mode BUGFIX: Apnea total divetime BUGFIX: Battery percent value with 3,6V battery NEW: Surface customview with important deco settings [0.98] New: Add cardinal (and ordinal) directions for the compass [0.97] NEW: compass gain option to work with more magnetic battery types BUGFIX: fix imperial units in logbook [0.96] NEW: calm compass reading for minor heading changes NEW: reduce eco low brightness threshold (for cave diving) [0.95] BUGFIX: Show "MOD:" instead of "EAD:" in gas setup [0.94] CHANGE: Show Max. Depth with 0.1m precision [0.91] BUGFIX: Battery percents in cold water [0.93] BUGFIX: Custom text <60 chars BUGFIX: Logbook PC protocol Italian language updates BUGFIX: Timeout in decoplanner result page