Mercurial > public > hwos_code
view src/calibrate.asm @ 596:2b4e02a9c1e4
italian update
author | heinrichsweikamp |
---|---|
date | Tue, 03 Jul 2018 09:49:34 +0200 |
parents | b455b31ce022 |
children | ca4556fb60b9 |
line wrap: on
line source
;============================================================================= ; ; File calibration.asm REFACTORED VERSION V2.98 ; ; o2 sensor calibration subroutines ; ; Copyright (c) 2014, Heinrichs Weikamp, all right reserved. ;============================================================================= #include "hwos.inc" #include "shared_definitions.h" ; Mailbox between c and asm #include "math.inc" #include "adc_lightsensor.inc" #include "eeprom_rs232.inc" calibrate CODE global check_sensors ; Check O2 sensor thresholds for fallback and voting logic check_sensors: ; Check min_mv movff o2_mv_sensor1+0, sub_a+0 movff o2_mv_sensor1+1, sub_a+1 movlw LOW min_mv movwf sub_b+0 movlw HIGH min_mv movwf sub_b+1 call sub16 ; sub_c = sub_a - sub_b bsf use_O2_sensor1 ;=1: Use this sensor for deco btfsc neg_flag bcf use_O2_sensor1 ;=1: Use this sensor for deco movff o2_mv_sensor2+0, sub_a+0 movff o2_mv_sensor2+1, sub_a+1 movlw LOW min_mv movwf sub_b+0 movlw HIGH min_mv movwf sub_b+1 call sub16 ; sub_c = sub_a - sub_b bsf use_O2_sensor2 ;=1: Use this sensor for deco btfsc neg_flag bcf use_O2_sensor2 ;=1: Use this sensor for deco movff o2_mv_sensor3+0, sub_a+0 movff o2_mv_sensor3+1, sub_a+1 movlw LOW min_mv movwf sub_b+0 movlw HIGH min_mv movwf sub_b+1 call sub16 ; sub_c = sub_a - sub_b bsf use_O2_sensor3 ;=1: Use this sensor for deco btfsc neg_flag bcf use_O2_sensor3 ;=1: Use this sensor for deco ; Check max_mv movff o2_mv_sensor1+0, sub_a+0 movff o2_mv_sensor1+1, sub_a+1 movlw LOW max_mv movwf sub_b+0 movlw HIGH max_mv movwf sub_b+1 call sub16 ; sub_c = sub_a - sub_b btfss neg_flag bcf use_O2_sensor1 ;=1: Use this sensor for deco movff o2_mv_sensor2+0, sub_a+0 movff o2_mv_sensor2+1, sub_a+1 movlw LOW max_mv movwf sub_b+0 movlw HIGH max_mv movwf sub_b+1 call sub16 ; sub_c = sub_a - sub_b btfss neg_flag bcf use_O2_sensor2 ;=1: Use this sensor for deco movff o2_mv_sensor3+0, sub_a+0 movff o2_mv_sensor3+1, sub_a+1 movlw LOW max_mv movwf sub_b+0 movlw HIGH max_mv movwf sub_b+1 call sub16 ; sub_c = sub_a - sub_b btfss neg_flag bcf use_O2_sensor3 ;=1: Use this sensor for deco btfss hud_connection_ok ;=1: HUD connection ok bra check_sensor2 ; No HUD/Digital data ; Copy disable flags from digital input btfss sensor1_active bcf use_O2_sensor1 btfss sensor2_active bcf use_O2_sensor2 btfss sensor3_active bcf use_O2_sensor3 return check_sensor2: ; Copy disable flags from internal calibration routine btfss sensor1_calibrated_ok bcf use_O2_sensor1 btfss sensor2_calibrated_ok bcf use_O2_sensor2 btfss sensor3_calibrated_ok bcf use_O2_sensor3 return global calibrate_mix calibrate_mix: ; calibrate S8 HUD btfss s8_digital ; S8 Digital? bra calibrate_mix2 ; No ; Yes, calibrate any S8-connected HUD clrf lo ; Checksum movlw 0xAA ; Start Byte addwf lo,F movff WREG,TXREG2 call rs232_wait_tx2 movlw 0x31 ; Calibrate addwf lo,F movff WREG,TXREG2 call rs232_wait_tx2 movff opt_calibration_O2_ratio,WREG ; Calibration gas %O2 addwf lo,F movff WREG,TXREG2 call rs232_wait_tx2 movff amb_pressure+0,WREG ; Ambient pressure addwf lo,F movff WREG,TXREG2 call rs232_wait_tx2 movff amb_pressure+1,WREG addwf lo,F movff WREG,TXREG2 call rs232_wait_tx2 movff lo,TXREG2 ; Checksum call rs232_wait_tx2 calibrate_mix2: movff opt_calibration_O2_ratio,WREG ; Calibration gas %O2 mullw .100 movff PRODL,xA+0 movff PRODH,xA+1 ; (%O2*100)*[ambient,mbar]/100 -> xC movff amb_pressure+0,xB+0 movff amb_pressure+1,xB+1 rcall calibrate_mix2_helper movff o2_mv_sensor1+0,xB+0 movff o2_mv_sensor1+1,xB+1 call div32x16 ; xC:4 / xB:2 = xC+3:xC+2 with xC+1:xC+0 as remainder ; xC= ppO2/mV movff xC+0,opt_x_s1+0 movff xC+1,opt_x_s1+1 ; Factor for Sensor1 movff opt_calibration_O2_ratio,WREG ; Calibration gas %O2 mullw .100 movff PRODL,xA+0 movff PRODH,xA+1 ; (%O2*100)*[ambient,mbar]/100 -> xC movff amb_pressure+0,xB+0 movff amb_pressure+1,xB+1 rcall calibrate_mix2_helper movff o2_mv_sensor2+0,xB+0 movff o2_mv_sensor2+1,xB+1 call div32x16 ; xC:4 / xB:2 = xC+3:xC+2 with xC+1:xC+0 as remainder ; xC= ppO2/mV movff xC+0,opt_x_s2+0 movff xC+1,opt_x_s2+1 ; Factor for Sensor2 movff opt_calibration_O2_ratio,WREG ; Calibration gas %O2 mullw .100 movff PRODL,xA+0 movff PRODH,xA+1 ; (%O2*100)*[ambient,mbar]/100 -> xC movff amb_pressure+0,xB+0 movff amb_pressure+1,xB+1 rcall calibrate_mix2_helper movff o2_mv_sensor3+0,xB+0 movff o2_mv_sensor3+1,xB+1 call div32x16 ; xC:4 / xB:2 = xC+3:xC+2 with xC+1:xC+0 as remainder ; xC= ppO2/mV movff xC+0,opt_x_s3+0 movff xC+1,opt_x_s3+1 ; Factor for Sensor3 bsf sensor1_calibrated_ok bsf sensor2_calibrated_ok bsf sensor3_calibrated_ok ; Set flags prior check rcall check_sensors ; Check O2 sensor thresholds min_mv and max_mv and set use_02_sensorX flags ; initialize internal calibration flags btfss use_O2_sensor1 ; Sensor out of range? bcf sensor1_calibrated_ok ; Yes, disable this sensor btfss use_O2_sensor2 ; Sensor out of range? bcf sensor2_calibrated_ok ; Yes, disable this sensor btfss use_O2_sensor3 ; Sensor out of range? bcf sensor3_calibrated_ok ; Yes, disable this sensor ; When no sensor is found, enable all three to show error state btfsc use_O2_sensor1 return btfsc use_O2_sensor2 return btfsc use_O2_sensor3 return bsf use_O2_sensor1 bsf use_O2_sensor2 bsf use_O2_sensor3 ; Clear factors banksel opt_x_s1+0 clrf opt_x_s1+0 clrf opt_x_s1+1 clrf opt_x_s2+0 clrf opt_x_s2+1 clrf opt_x_s3+0 clrf opt_x_s3+1 banksel common return calibrate_mix2_helper: call mult16x16 ; xA*xB=xC movlw LOW .100 movwf xB+0 movlw HIGH .100 movwf xB+1 goto div32x16 ; xC:4 / xB:2 = xC+3:xC+2 with xC+1:xC+0 as remainder (And return) global compute_mvolts_for_all_sensors compute_mvolts_for_all_sensors: ; Compute mV or all sensors (S8 Mode) ; compute AD results in 100µV steps (16bit/sensor) ; 24bit AD result is in 244,1406541nV ; Divide 24bit value through 409,5999512 -> 410 (0,01% error) #DEFINE ad2mv_factor .410 ; Sensor 1 clrf xC+3 movff s8_rawdata_sensor1+2,xC+2 movff s8_rawdata_sensor1+1,xC+1 movff s8_rawdata_sensor1+0,xC+0 movlw LOW ad2mv_factor movwf xB+0 movlw HIGH ad2mv_factor movwf xB+1 call div32x16 ; xC:4 / xB:2 = xC+3:xC+2 with xC+1:xC+0 as remainder movff xC+1,o2_mv_sensor1+1 movff xC+0,o2_mv_sensor1+0 ; in 100uV steps ; Sensor 2 clrf xC+3 movff s8_rawdata_sensor2+2,xC+2 movff s8_rawdata_sensor2+1,xC+1 movff s8_rawdata_sensor2+0,xC+0 movlw LOW ad2mv_factor movwf xB+0 movlw HIGH ad2mv_factor movwf xB+1 call div32x16 ; xC:4 / xB:2 = xC+3:xC+2 with xC+1:xC+0 as remainder movff xC+1,o2_mv_sensor2+1 movff xC+0,o2_mv_sensor2+0 ; in 100uV steps ; Sensor 3 clrf xC+3 movff s8_rawdata_sensor3+2,xC+2 movff s8_rawdata_sensor3+1,xC+1 movff s8_rawdata_sensor3+0,xC+0 movlw LOW ad2mv_factor movwf xB+0 movlw HIGH ad2mv_factor movwf xB+1 call div32x16 ; xC:4 / xB:2 = xC+3:xC+2 with xC+1:xC+0 as remainder movff xC+1,o2_mv_sensor3+1 movff xC+0,o2_mv_sensor3+0 ; in 100uV steps bcf new_s8_data_available ; Clear flag return ; Done. global transmit_setpoint ; Transmit current setpoint from WREG (in cbar) to external electronics transmit_setpoint: return ; !!!! FUNCTION IS CURRENTLY DISABLED !!!! btfss s8_digital ; S8 Digital? return ; No, ignore ; Yes, transmit setpoint from WREG movwf hi ; Store setpoint clrf lo ; Checksum movlw 0xAA ; Start Byte addwf lo,F movff WREG,TXREG2 call rs232_wait_tx2 movlw 0x60 ; New SP addwf lo,F movff WREG,TXREG2 call rs232_wait_tx2 movff hi,WREG ; SP in cbar addwf lo,F movff WREG,TXREG2 call rs232_wait_tx2 movff lo,TXREG2 ; Checksum call rs232_wait_tx2 return END