diff src/option_table.asm @ 399:db25f2028074

CHANGE: New segmented speed graph in divemode NEW: Safety Stop can be configured (Start-, End- and reset-depth + length of stop) via PC
author heinrichsweikamp
date Tue, 24 Nov 2015 16:22:52 +0100
parents 57e349960ef4
children d93d75ae01bf
line wrap: on
line diff
--- a/src/option_table.asm	Mon Nov 23 16:13:25 2015 +0100
+++ b/src/option_table.asm	Tue Nov 24 16:22:52 2015 +0100
@@ -204,6 +204,10 @@
         OPTION_BOOL     oVSIgraph,      0,                            .158,    opt_vsigraph                     ; =1: draw the graphical VSI bar
         OPTION_BOOL     oShowppO2,      0,                            .159,    opt_showppo2                     ; =1:always show the ppO2 value in the warning position
         OPTION_UINT8    oTemperatureAdjust, .0,.255,   .0,     -1,    .160,    opt_temperature_adjust           ; SIGNED int (-2.0/+2.0 °C max.)
+        OPTION_UINT8    oSafetyStopLength, .60,.240,   .180,   -1,    .161,    opt_safety_stop_length           ; [s]
+        OPTION_UINT8    oSafetyStopStart,  .21,.61,     .51,   -1,    .162,    opt_safety_stop_start            ; [cbar], default 510mbar, min 210mbar, max 610mbar
+        OPTION_UINT8    oSafetyStopEnd,    .19,.39,     .29,   -1,    .163,    opt_safety_stop_end              ; [cbar], default 290mbar, min 190mbar, max 390mbar
+        OPTION_UINT8    oSafetyStopReset,  .81,.151,    .101,  -1,    .164,    opt_safety_stop_reset            ; [cbar], default 1010mbar, min 810mbar, max 1510mbar
 
 
 ;=============================================================================