Mercurial > public > hwos_code
diff doc/Changenote-3-08.txt @ 631:185ba2f91f59
3.09 beta 1 release
author | heinrichsweikamp |
---|---|
date | Fri, 28 Feb 2020 15:45:07 +0100 |
parents | |
children | 0347acdf6d8e |
line wrap: on
line diff
--- /dev/null Thu Jan 01 00:00:00 1970 +0000 +++ b/doc/Changenote-3-08.txt Fri Feb 28 15:45:07 2020 +0100 @@ -0,0 +1,66 @@ +Change Note hwos TECH Firmware 3.08 +==================================== + +- Removed option 'ascent speed', ascent calculation is done with a fixed + speed of 10 meters/minute now (equals the ascent speed limit by Bühlmann). + +- Improved calculation accuracy of the initial ascent. Remark: this will + have a slight impact on the resulting deco schedule compared to firmware + 3.07. + +- The deco calculator now figures in the salinity setting. + +- Aligned logbook and last dive summery of avg and max depth regarding + rounding and incorporation of salinity setting. + +- Done some fine-tuning of depth outputs when using imperial units (feet). + +- In dive mode, sometimes the temperature was not shown any more after a + gas change - fixed now. + +- The menu system around setting up the dive mode & settings has been + decluttered. All settings are now sorted into the groups dive setup, + deco setup, SAC (gas needs) setup, ppO2 setup and stops & depths setup. + +- There is a new option "Swap on empty" in Dive Setup -> SAC Setup. + It is only effective if "CalcGas(B/O)" is switched on, too. If both + options are switched on, the deco calculation will switch to another + tank (i.e. gas) once the tank of the current gas is calculated to be + used up. + This function can be used to automatically calculate a contingency in + case of running out of a deco gas, as the deco calculation will then + continue to calculate a deco making use of the spares from the another + gases carried. Another application is with two or more tanks holding + the same gas (i.e. independent double configuration, side-mount), as + the calculations will then take the cumulative amount of gas carried + into account before raising a gas needs attention or alarm. + +- Fixed the urge of the better gas hint to always favor one specific gas + out of a set of two or more gases that have the same change depth. + +- For dives done on firmware >= 3.08 the logbook will have one more page + showing the tissue pressures and supersaturation levels as of at the + end of dive (i.e. when surfacing). + +- As long as a gas or diluent is currently selected as breathed, it can + not be set into the lost state any more. + +- When changing the battery or doing a cold start, the current CNS value + does not get lost any more. + +- During loading of a new firmware the clock will not loose time any more + (on old firmware it became late by about 15 sec on each firmware update). + +- When run from a 3.6 V battery (either replaceable or built-in), the + surface mode timeout is now extended to 4 minutes before going to sleep + mode. If the OSTC is run from 1.5 V disposables, the timeout remains at + the previous 90 seconds to save on battery runtime. + +- Internal improvement: the code for the internal storage system and for + the communication system (firmware uploading, dive data downloading) + has been re-factored to secure maintainability for the next years to come. + +- Internal improvement: the scheduler for the dive mode calculation plans + (fTTS, bailout) has been completely rewritten for better maintainability. + +- Brand new feature: Cave Mode. See supplemental manual for further details. \ No newline at end of file