comparison src/option_table.asm @ 533:dfac393b2199

CHANGE: CCR Calibration gas range limited to O2% 21-25 and 95-100 to save button presses Layout adjustsments in divemode (CCR ppO2(Dil)
author heinrichsweikamp
date Mon, 21 Aug 2017 14:55:36 +0200
parents 4e6f5c36f4cc
children b7eb98dbd800
comparison
equal deleted inserted replaced
532:72ae62440597 533:dfac393b2199
194 ;============================================================================= 194 ;=============================================================================
195 ; Misc 195 ; Misc
196 OPTION_ENUM8 oColorSetDive, 4, 0, tColorSetName0, .146, opt_dive_color_scheme ; Color scheme divemode 196 OPTION_ENUM8 oColorSetDive, 4, 0, tColorSetName0, .146, opt_dive_color_scheme ; Color scheme divemode
197 OPTION_UINT8 oPressureAdjust, .0,.255, .0, -1, .147, opt_pressure_adjust ; SIGNED int (-20/+20mbar max.) 197 OPTION_UINT8 oPressureAdjust, .0,.255, .0, -1, .147, opt_pressure_adjust ; SIGNED int (-20/+20mbar max.)
198 OPTION_BOOL oSafetyStop, 0, .148, opt_enable_safetystop ; =1: A safety stop is shown 198 OPTION_BOOL oSafetyStop, 0, .148, opt_enable_safetystop ; =1: A safety stop is shown
199 OPTION_UINT8 oCalGasO2, .21,.100, .21, tPercent, .149, opt_calibration_O2_ratio ; Calibration gas %O2 199 OPTION_UINT8 oCalGasO2, .21,.100, .21, tPercent, .149, opt_calibration_O2_ratio ; Calibration gas %O2 (Do not move in EEPROM, must stay at .149!)
200 OPTION_BOOL oSensorFallback,1, .150, opt_sensor_fallback ; =1: Fallback to SP1 when sensor is lost 200 OPTION_BOOL oSensorFallback,1, .150, opt_sensor_fallback ; =1: Fallback to SP1 when sensor is lost
201 OPTION_BOOL oFlipScreen, 0, .151, opt_flip_screen ; =1: Flip the screen 201 OPTION_BOOL oFlipScreen, 0, .151, opt_flip_screen ; =1: Flip the screen
202 OPTION_UINT8p10 ocR_button_left, .20, .100, .40, tPercent, .152, opt_cR_button_left ; left button sensitivity 202 OPTION_UINT8p10 ocR_button_left, .20, .100, .40, tPercent, .152, opt_cR_button_left ; left button sensitivity
203 OPTION_UINT8p10 ocR_button_right,.20, .100, .40, tPercent, .153, opt_cR_button_right ; right button sensitivity 203 OPTION_UINT8p10 ocR_button_right,.20, .100, .40, tPercent, .153, opt_cR_button_right ; right button sensitivity
204 OPTION_UINT8 obottom_usage, .5,.50, .20,tLitersMinute, .154, char_I_bottom_usage ; l/min 204 OPTION_UINT8 obottom_usage, .5,.50, .20,tLitersMinute, .154, char_I_bottom_usage ; l/min