CHANGE: CCR Calibration gas range limited to O2% 21-25 and 95-100 to save button presses
Layout adjustsments in divemode (CCR ppO2(Dil)
author | heinrichsweikamp |
---|---|
date | Mon, 21 Aug 2017 14:55:36 +0200 |
parents | 4e6f5c36f4cc |
children | b7eb98dbd800 |
comparison
equal
deleted
inserted
replaced
532:72ae62440597 | 533:dfac393b2199 |
---|---|
194 ;============================================================================= | 194 ;============================================================================= |
195 ; Misc | 195 ; Misc |
196 OPTION_ENUM8 oColorSetDive, 4, 0, tColorSetName0, .146, opt_dive_color_scheme ; Color scheme divemode | 196 OPTION_ENUM8 oColorSetDive, 4, 0, tColorSetName0, .146, opt_dive_color_scheme ; Color scheme divemode |
197 OPTION_UINT8 oPressureAdjust, .0,.255, .0, -1, .147, opt_pressure_adjust ; SIGNED int (-20/+20mbar max.) | 197 OPTION_UINT8 oPressureAdjust, .0,.255, .0, -1, .147, opt_pressure_adjust ; SIGNED int (-20/+20mbar max.) |
198 OPTION_BOOL oSafetyStop, 0, .148, opt_enable_safetystop ; =1: A safety stop is shown | 198 OPTION_BOOL oSafetyStop, 0, .148, opt_enable_safetystop ; =1: A safety stop is shown |
199 OPTION_UINT8 oCalGasO2, .21,.100, .21, tPercent, .149, opt_calibration_O2_ratio ; Calibration gas %O2 | 199 OPTION_UINT8 oCalGasO2, .21,.100, .21, tPercent, .149, opt_calibration_O2_ratio ; Calibration gas %O2 (Do not move in EEPROM, must stay at .149!) |
200 OPTION_BOOL oSensorFallback,1, .150, opt_sensor_fallback ; =1: Fallback to SP1 when sensor is lost | 200 OPTION_BOOL oSensorFallback,1, .150, opt_sensor_fallback ; =1: Fallback to SP1 when sensor is lost |
201 OPTION_BOOL oFlipScreen, 0, .151, opt_flip_screen ; =1: Flip the screen | 201 OPTION_BOOL oFlipScreen, 0, .151, opt_flip_screen ; =1: Flip the screen |
202 OPTION_UINT8p10 ocR_button_left, .20, .100, .40, tPercent, .152, opt_cR_button_left ; left button sensitivity | 202 OPTION_UINT8p10 ocR_button_left, .20, .100, .40, tPercent, .152, opt_cR_button_left ; left button sensitivity |
203 OPTION_UINT8p10 ocR_button_right,.20, .100, .40, tPercent, .153, opt_cR_button_right ; right button sensitivity | 203 OPTION_UINT8p10 ocR_button_right,.20, .100, .40, tPercent, .153, opt_cR_button_right ; right button sensitivity |
204 OPTION_UINT8 obottom_usage, .5,.50, .20,tLitersMinute, .154, char_I_bottom_usage ; l/min | 204 OPTION_UINT8 obottom_usage, .5,.50, .20,tLitersMinute, .154, char_I_bottom_usage ; l/min |