1 Change Note hwos Firmware 3.09.4 | |
2 ================================ | |
3 | |
4 - When diving in CCR or pSCR mode: An attention and a warning for the gas | |
5 density has been added. The attention will be given when the density | |
6 of the current gas mixture reaches 6.0 grams per liter. Upon reaching | |
7 6.5 grams per liter, a warning will be given. The checks can be enabled | |
8 or disabled via the menu CCR/pSCR setup > more. | |
9 | |
10 - Incremented upper limit for SAC Work to 80 l/min to ease usage of the | |
11 OSTC gas needs calculation in Rock-Bottom mode. | |
12 | |
13 - Faster response to button events while in dive mode. | |
14 | |
15 - Hardened all USB/Bluetooth communication against data losses and timeouts. | |
16 | |
17 - Fixed Bluetooth item disappearing from menu. | |
18 | |
19 - A new Firmware Recovery Feature has been added: the currently active firmware | |
20 can be backed-up and restored later on while other firmwares have been loaded | |
21 thereafter. The feature is accessible via Settings -> System Settings -> | |
22 Reset Menu -> Reboot and becomes available with the first firmware load after | |
23 the V3.09 beta 4 (or later) is already on the unit. | |
24 | |
25 | |
26 Change Note hwos Firmware 3.09.2 + 3.09.3 | |
27 ========================================= | |
28 | |
29 - Added a function to acknowledge pending alarms, attentions and advices | |
30 so that the exclamation-mark sign disappears: after pressing the left | |
31 button until "Ackn?" appears, a press on the right button acknowledges | |
32 the current alarm, attention or advice and suppresses the related sign. | |
33 | |
34 - Bugfixes: NDL not shown in big layout, external sensor not selectable, | |
35 flash-write operation on some OSTC hardware, graphical garbage in depth | |
36 output in big layout when deeper than 100 m. | |
37 | |
38 | |
39 Change Note hwos Firmware 3.09.1 | |
40 ================================ | |
41 | |
42 - Removed option 'ascent speed', ascent calculation is done with a fixed | |
43 speed of 10 meters/minute now (equals the ascent speed limit by Bühlmann). | |
44 | |
45 - Improved calculation accuracy of the initial ascent. Remark: this will | |
46 have a slight impact on the resulting deco schedule compared to firmware | |
47 3.07. | |
48 | |
49 - The deco calculator now figures in the salinity setting. | |
50 | |
51 - Aligned logbook and last dive summery of avg and max depth regarding | |
52 rounding and incorporation of salinity setting. | |
53 | |
54 - Done some fine-tuning of depth outputs when using imperial units (feet). | |
55 | |
56 - In dive mode, sometimes the temperature was not shown any more after a | |
57 gas change - fixed now. | |
58 | |
59 - The menu system around setting up the dive mode & settings has been | |
60 decluttered. All settings are now sorted into the groups dive setup, | |
61 deco setup, SAC (gas needs) setup, ppO2 setup and stops & depths setup. | |
62 | |
63 - There is a new option "Swap on empty" in Dive Setup -> SAC Setup. | |
64 It is only effective if "CalcGas(B/O)" is switched on, too. If both | |
65 options are switched on, the deco calculation will switch to another | |
66 tank (i.e. gas) once the tank of the current gas is calculated to be | |
67 used up. | |
68 This function can be used to automatically calculate a contingency in | |
69 case of running out of a deco gas, as the deco calculation will then | |
70 continue to calculate a deco making use of the spares from the another | |
71 gases carried. Another application is with two or more tanks holding | |
72 the same gas (i.e. independent double configuration, side-mount), as | |
73 the calculations will then take the cumulative amount of gas carried | |
74 into account before raising a gas needs attention or alarm. | |
75 | |
76 - Fixed the urge of the better gas hint to always favor one specific gas | |
77 out of a set of two or more gases that have the same change depth. | |
78 | |
79 - For dives done on firmware >= 3.09 the logbook will have one more page | |
80 showing the tissue pressures and supersaturation levels as of at the | |
81 end of dive (i.e. when surfacing). | |
82 | |
83 - As long as a gas or diluent is currently selected as breathed, it can | |
84 not be set into the lost state any more. | |
85 | |
86 - When changing the battery or doing a cold start, the current CNS value | |
87 does not get lost any more. | |
88 | |
89 - During loading of a new firmware the clock will not loose time any more | |
90 (on old firmware it became late by about 15 sec on each firmware update). | |
91 | |
92 - When run from a 3.6 V battery (either replaceable or built-in), the | |
93 surface mode timeout is now extended to 4 minutes before going to sleep | |
94 mode. If the OSTC is run from 1.5 V disposables, the timeout remains at | |
95 the previous 90 seconds to save on battery runtime. | |
96 | |
97 - Internal improvement: the code for the internal storage system and for | |
98 the communication system (firmware uploading, dive data downloading) | |
99 has been re-factored to secure maintainability for the next years to come. | |
100 | |
101 - Internal improvement: the scheduler for the dive mode calculation plans | |
102 (fTTS, bailout) has been completely rewritten for better maintainability. |