3.10 stable release
| author | heinrichsweikamp |
|---|---|
| date | Tue, 28 Apr 2020 17:34:31 +0200 |
| parents | |
| children |
comparison
equal
deleted
inserted
replaced
| 633:690c48db7b5b | 634:4050675965ea |
|---|---|
| 1 Change Note hwos TECH Firmware 3.08 | |
| 2 ==================================== | |
| 3 | |
| 4 - Removed option 'ascent speed', ascent calculation is done with a fixed | |
| 5 speed of 10 meters/minute now (equals the ascent speed limit by Bühlmann). | |
| 6 | |
| 7 - Improved calculation accuracy of the initial ascent. Remark: this will | |
| 8 have a slight impact on the resulting deco schedule compared to firmware | |
| 9 3.07. | |
| 10 | |
| 11 - The deco calculator now figures in the salinity setting. | |
| 12 | |
| 13 - Aligned logbook and last dive summery of avg and max depth regarding | |
| 14 rounding and incorporation of salinity setting. | |
| 15 | |
| 16 - Done some fine-tuning of depth outputs when using imperial units (feet). | |
| 17 | |
| 18 - In dive mode, sometimes the temperature was not shown any more after a | |
| 19 gas change - fixed now. | |
| 20 | |
| 21 - The menu system around setting up the dive mode & settings has been | |
| 22 decluttered. All settings are now sorted into the groups dive setup, | |
| 23 deco setup, SAC (gas needs) setup, ppO2 setup and stops & depths setup. | |
| 24 | |
| 25 - There is a new option "Swap on empty" in Dive Setup -> SAC Setup. | |
| 26 It is only effective if "CalcGas(B/O)" is switched on, too. If both | |
| 27 options are switched on, the deco calculation will switch to another | |
| 28 tank (i.e. gas) once the tank of the current gas is calculated to be | |
| 29 used up. | |
| 30 This function can be used to automatically calculate a contingency in | |
| 31 case of running out of a deco gas, as the deco calculation will then | |
| 32 continue to calculate a deco making use of the spares from the another | |
| 33 gases carried. Another application is with two or more tanks holding | |
| 34 the same gas (i.e. independent double configuration, side-mount), as | |
| 35 the calculations will then take the cumulative amount of gas carried | |
| 36 into account before raising a gas needs attention or alarm. | |
| 37 | |
| 38 - Fixed the urge of the better gas hint to always favor one specific gas | |
| 39 out of a set of two or more gases that have the same change depth. | |
| 40 | |
| 41 - For dives done on firmware >= 3.08 the logbook will have one more page | |
| 42 showing the tissue pressures and supersaturation levels as of at the | |
| 43 end of dive (i.e. when surfacing). | |
| 44 | |
| 45 - As long as a gas or diluent is currently selected as breathed, it can | |
| 46 not be set into the lost state any more. | |
| 47 | |
| 48 - When changing the battery or doing a cold start, the current CNS value | |
| 49 does not get lost any more. | |
| 50 | |
| 51 - During loading of a new firmware the clock will not loose time any more | |
| 52 (on old firmware it became late by about 15 sec on each firmware update). | |
| 53 | |
| 54 - When run from a 3.6 V battery (either replaceable or built-in), the | |
| 55 surface mode timeout is now extended to 4 minutes before going to sleep | |
| 56 mode. If the OSTC is run from 1.5 V disposables, the timeout remains at | |
| 57 the previous 90 seconds to save on battery runtime. | |
| 58 | |
| 59 - Internal improvement: the code for the internal storage system and for | |
| 60 the communication system (firmware uploading, dive data downloading) | |
| 61 has been re-factored to secure maintainability for the next years to come. | |
| 62 | |
| 63 - Internal improvement: the scheduler for the dive mode calculation plans | |
| 64 (fTTS, bailout) has been completely rewritten for better maintainability. | |
| 65 | |
| 66 - Brand new feature: Cave Mode. See supplemental manual for further details. |