Mercurial > public > hwos_code
comparison src/isr.asm @ 565:0ba88db66492
CHANGE: Limit button sensitivity to 80%
author | heinrichsweikamp |
---|---|
date | Tue, 06 Feb 2018 10:07:38 +0100 |
parents | b7eb98dbd800 |
children | c8ea60294175 |
comparison
equal
deleted
inserted
replaced
564:54346c651b6a | 565:0ba88db66492 |
---|---|
358 btfss analog_o2_input | 358 btfss analog_o2_input |
359 bra isr_tmr7_1a ; Always with normal ostc3 hardware | 359 bra isr_tmr7_1a ; Always with normal ostc3 hardware |
360 btfss s8_digital | 360 btfss s8_digital |
361 bra isr_tmr7_2 ; only when digital | 361 bra isr_tmr7_2 ; only when digital |
362 isr_tmr7_1a: | 362 isr_tmr7_1a: |
363 clrf o2_mv_sensor1+0 | 363 clrf o2_mv_sensor1+0 ; S8/IR timeout clears all analog input readings to zero -> Fallback will be triggered when sensor mode was used |
364 clrf o2_mv_sensor1+1 | 364 clrf o2_mv_sensor1+1 |
365 clrf o2_mv_sensor2+0 | 365 clrf o2_mv_sensor2+0 |
366 clrf o2_mv_sensor2+1 | 366 clrf o2_mv_sensor2+1 |
367 clrf o2_mv_sensor3+0 | 367 clrf o2_mv_sensor3+0 |
368 clrf o2_mv_sensor3+1 | 368 clrf o2_mv_sensor3+1 |
369 banksel hud_battery_mv | 369 banksel hud_battery_mv |
370 clrf hud_battery_mv+0 | 370 clrf hud_battery_mv+0 |
371 clrf hud_battery_mv+1 | 371 clrf hud_battery_mv+1 |
372 banksel hud_status_byte | 372 banksel hud_status_byte |
373 clrf hud_status_byte | 373 clrf hud_status_byte |
374 clrf o2_ppo2_sensor1 | 374 clrf o2_ppo2_sensor1 ; For IR/S8 HUD |
375 clrf o2_ppo2_sensor2 | 375 clrf o2_ppo2_sensor2 |
376 clrf o2_ppo2_sensor3 | 376 clrf o2_ppo2_sensor3 |
377 | 377 |
378 isr_tmr7_2: | 378 isr_tmr7_2: |
379 banksel common | 379 banksel common |