21 - The menu system around setting up the dive mode & settings has been | 21 - The menu system around setting up the dive mode & settings has been |
22 decluttered. All settings are now sorted into the groups dive setup, | 22 decluttered. All settings are now sorted into the groups dive setup, |
23 deco setup, SAC (gas needs) setup, ppO2 setup and stops & depths setup. | 23 deco setup, SAC (gas needs) setup, ppO2 setup and stops & depths setup. |
24 | 24 |
25 - There is a new option "Swap on empty" in Dive Setup -> SAC Setup. | |
26 It is only effective if "CalcGas(B/O)" is switched on, too. If both | |
27 options are switched on, the deco calculation will switch to another | |
28 tank (i.e. gas) once the tank of the current gas is calculated to be | |
29 used up. | |
30 This function can be used to automatically calculate a contingency in | |
31 case of running out of a deco gas, as the deco calculation will then | |
32 continue to calculate a deco making use of the spares from the another | |
33 gases carried. Another application is with two or more tanks holding | |
34 the same gas (i.e. independent double configuration, side-mount), as | |
35 the calculations will then take the cumulative amount of gas carried | |
36 into account before raising a gas needs attention or alarm. | |
37 | |
38 - Fixed the urge of the better gas hint to always favor one specific gas | 25 - Fixed the urge of the better gas hint to always favor one specific gas |
39 out of a set of two or more gases that have the same change depth. | 26 out of a set of two or more gases that have the same change depth. |
40 | 27 |
41 - For dives done on firmware >= 3.08 the logbook will have one more page | 28 - For dives done on firmware >= 3.09 the logbook will have one more page |
42 showing the tissue pressures and supersaturation levels as of at the | 29 showing the tissue pressures and supersaturation levels as of at the |
43 end of dive (i.e. when surfacing). | 30 end of dive (i.e. when surfacing). |
44 | 31 |
45 - As long as a gas or diluent is currently selected as breathed, it can | 32 - As long as a gas or diluent is currently selected as breathed, it can |
46 not be set into the lost state any more. | 33 not be set into the lost state any more. |