631
|
1 Change Note hwos TECH Firmware 3.08
|
|
2 ====================================
|
|
3
|
|
4 - Removed option 'ascent speed', ascent calculation is done with a fixed
|
|
5 speed of 10 meters/minute now (equals the ascent speed limit by Bühlmann).
|
|
6
|
|
7 - Improved calculation accuracy of the initial ascent. Remark: this will
|
|
8 have a slight impact on the resulting deco schedule compared to firmware
|
|
9 3.07.
|
|
10
|
|
11 - The deco calculator now figures in the salinity setting.
|
|
12
|
|
13 - Aligned logbook and last dive summery of avg and max depth regarding
|
|
14 rounding and incorporation of salinity setting.
|
|
15
|
|
16 - Done some fine-tuning of depth outputs when using imperial units (feet).
|
|
17
|
|
18 - In dive mode, sometimes the temperature was not shown any more after a
|
|
19 gas change - fixed now.
|
|
20
|
|
21 - The menu system around setting up the dive mode & settings has been
|
|
22 decluttered. All settings are now sorted into the groups dive setup,
|
|
23 deco setup, SAC (gas needs) setup, ppO2 setup and stops & depths setup.
|
|
24
|
|
25 - Fixed the urge of the better gas hint to always favor one specific gas
|
|
26 out of a set of two or more gases that have the same change depth.
|
|
27
|
632
|
28 - For dives done on firmware >= 3.09 the logbook will have one more page
|
631
|
29 showing the tissue pressures and supersaturation levels as of at the
|
|
30 end of dive (i.e. when surfacing).
|
|
31
|
|
32 - As long as a gas or diluent is currently selected as breathed, it can
|
|
33 not be set into the lost state any more.
|
|
34
|
|
35 - When changing the battery or doing a cold start, the current CNS value
|
|
36 does not get lost any more.
|
|
37
|
|
38 - During loading of a new firmware the clock will not loose time any more
|
|
39 (on old firmware it became late by about 15 sec on each firmware update).
|
|
40
|
|
41 - When run from a 3.6 V battery (either replaceable or built-in), the
|
|
42 surface mode timeout is now extended to 4 minutes before going to sleep
|
|
43 mode. If the OSTC is run from 1.5 V disposables, the timeout remains at
|
|
44 the previous 90 seconds to save on battery runtime.
|
|
45
|
|
46 - Internal improvement: the code for the internal storage system and for
|
|
47 the communication system (firmware uploading, dive data downloading)
|
|
48 has been re-factored to secure maintainability for the next years to come.
|
|
49
|
|
50 - Internal improvement: the scheduler for the dive mode calculation plans
|
|
51 (fTTS, bailout) has been completely rewritten for better maintainability.
|
|
52
|
|