631
|
1 Change Note hwos TECH Firmware 3.08
|
|
2 ====================================
|
|
3
|
|
4 - Removed option 'ascent speed', ascent calculation is done with a fixed
|
|
5 speed of 10 meters/minute now (equals the ascent speed limit by Bühlmann).
|
|
6
|
|
7 - Improved calculation accuracy of the initial ascent. Remark: this will
|
|
8 have a slight impact on the resulting deco schedule compared to firmware
|
|
9 3.07.
|
|
10
|
|
11 - The deco calculator now figures in the salinity setting.
|
|
12
|
|
13 - Aligned logbook and last dive summery of avg and max depth regarding
|
|
14 rounding and incorporation of salinity setting.
|
|
15
|
|
16 - Done some fine-tuning of depth outputs when using imperial units (feet).
|
|
17
|
|
18 - In dive mode, sometimes the temperature was not shown any more after a
|
|
19 gas change - fixed now.
|
|
20
|
|
21 - The menu system around setting up the dive mode & settings has been
|
|
22 decluttered. All settings are now sorted into the groups dive setup,
|
|
23 deco setup, SAC (gas needs) setup, ppO2 setup and stops & depths setup.
|
|
24
|
|
25 - There is a new option "Swap on empty" in Dive Setup -> SAC Setup.
|
|
26 It is only effective if "CalcGas(B/O)" is switched on, too. If both
|
|
27 options are switched on, the deco calculation will switch to another
|
|
28 tank (i.e. gas) once the tank of the current gas is calculated to be
|
|
29 used up.
|
|
30 This function can be used to automatically calculate a contingency in
|
|
31 case of running out of a deco gas, as the deco calculation will then
|
|
32 continue to calculate a deco making use of the spares from the another
|
|
33 gases carried. Another application is with two or more tanks holding
|
|
34 the same gas (i.e. independent double configuration, side-mount), as
|
|
35 the calculations will then take the cumulative amount of gas carried
|
|
36 into account before raising a gas needs attention or alarm.
|
|
37
|
|
38 - Fixed the urge of the better gas hint to always favor one specific gas
|
|
39 out of a set of two or more gases that have the same change depth.
|
|
40
|
|
41 - For dives done on firmware >= 3.08 the logbook will have one more page
|
|
42 showing the tissue pressures and supersaturation levels as of at the
|
|
43 end of dive (i.e. when surfacing).
|
|
44
|
|
45 - As long as a gas or diluent is currently selected as breathed, it can
|
|
46 not be set into the lost state any more.
|
|
47
|
|
48 - When changing the battery or doing a cold start, the current CNS value
|
|
49 does not get lost any more.
|
|
50
|
|
51 - During loading of a new firmware the clock will not loose time any more
|
|
52 (on old firmware it became late by about 15 sec on each firmware update).
|
|
53
|
|
54 - When run from a 3.6 V battery (either replaceable or built-in), the
|
|
55 surface mode timeout is now extended to 4 minutes before going to sleep
|
|
56 mode. If the OSTC is run from 1.5 V disposables, the timeout remains at
|
|
57 the previous 90 seconds to save on battery runtime.
|
|
58
|
|
59 - Internal improvement: the code for the internal storage system and for
|
|
60 the communication system (firmware uploading, dive data downloading)
|
|
61 has been re-factored to secure maintainability for the next years to come.
|
|
62
|
|
63 - Internal improvement: the scheduler for the dive mode calculation plans
|
|
64 (fTTS, bailout) has been completely rewritten for better maintainability.
|
|
65
|
|
66 - Brand new feature: Cave Mode. See supplemental manual for further details. |